Currently we have articles.ent and books.ent, and
for example, articles.ent can be used by putting the
following lines in the doctype declaration:
 <!ENTITY % articles.ent PUBLIC
            "-//FreeBSD//ENTITIES DocBook FreeBSD Articles Entity Set//EN">
 %articles.ent;
This pulls all of the necessary entities via share/sgml/articles.ent.
The translation teams can customize these entities by redefining
the articles.ent file in <langcode>/share/sgml.  See
ja_JP.eucJP/share/sgml for example.
		
	
			
		
			
				
	
	
		
			2643 lines
		
	
	
	
		
			107 KiB
		
	
	
	
		
			Text
		
	
	
	
	
	
			
		
		
	
	
			2643 lines
		
	
	
	
		
			107 KiB
		
	
	
	
		
			Text
		
	
	
	
	
	
| <!DOCTYPE article PUBLIC "-//FreeBSD//DTD DocBook V4.1-Based Extension//EN" [
 | |
| <!ENTITY % articles.ent PUBLIC "-//FreeBSD//ENTITIES DocBook FreeBSD Articles Entity Set//EN">
 | |
| %articles.ent;
 | |
| ]>
 | |
| 
 | |
| <article>
 | |
|   <articleinfo>
 | |
|     <title>Storage Devices</title>
 | |
|     
 | |
|     <authorgroup>
 | |
|       <author>
 | |
|         <firstname>Wilko</firstname>
 | |
|         <surname>Bulte</surname>
 | |
|         
 | |
|         <affiliation>
 | |
|           <address><email>wilko@FreeBSD.org</email></address>
 | |
|         </affiliation>
 | |
|       </author>
 | |
|     </authorgroup>
 | |
|     
 | |
|     <pubdate>$FreeBSD$</pubdate>
 | |
|     
 | |
| 
 | |
|     <legalnotice id="trademarks" role="trademarks">
 | |
|       &tm-attrib.freebsd;
 | |
|       &tm-attrib.general;
 | |
|     </legalnotice>
 | |
| 
 | |
|     <abstract>
 | |
|       <para>This article talks about storage devices with FreeBSD.</para>
 | |
|     </abstract>
 | |
|   </articleinfo>
 | |
|   
 | |
|   <sect1 id="esdi">
 | |
|     <title>Using ESDI hard disks</title>
 | |
|       
 | |
|     <para><emphasis>Copyright © 1995, &a.wilko;.  24 September
 | |
|       1995.</emphasis></para>
 | |
| 	  
 | |
|     <para>ESDI is an acronym that means Enhanced Small Device
 | |
|       Interface. It is loosely based on the good old ST506/412
 | |
|       interface originally devised by Seagate Technology, the makers
 | |
|       of the first affordable 5.25" winchester disk.</para>
 | |
| 	  
 | |
|     <para>The acronym says Enhanced, and rightly so.  In the first
 | |
|       place the speed of the interface is higher, 10 or 15
 | |
|       Mbits/second instead of the 5 Mbits/second of ST412 interfaced
 | |
|       drives.  Secondly some higher level commands are added, making
 | |
|       the ESDI interface somewhat <quote>smarter</quote> to the operating system
 | |
|       driver writers.  It is by no means as smart as SCSI by the way.
 | |
|       ESDI is standardized by ANSI.</para>
 | |
| 	  
 | |
|     <para>Capacities of the drives are boosted by putting more sectors
 | |
|       on each track.  Typical is 35 sectors per track, high capacity
 | |
|       drives I have seen were up to 54 sectors/track.</para>
 | |
|       
 | |
|     <para>Although ESDI has been largely obsoleted by IDE and SCSI
 | |
|       interfaces, the availability of free or cheap surplus drives
 | |
|       makes them ideal for low (or now) budget systems.</para>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Concepts of ESDI</title>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Physical connections</title>
 | |
| 	  
 | |
| 	  <para>The ESDI interface uses two cables connected to each drive.
 | |
| 	    One cable is a 34 pin flat cable edge connector that carries the
 | |
| 	    command and status signals from the controller to the drive and
 | |
| 	    vice-versa.  The command cable is daisy chained between all the
 | |
| 	    drives.  So, it forms a bus onto which all drives are
 | |
| 	    connected.</para>
 | |
| 	      
 | |
| 	  <para>The second cable is a 20 pin flat cable edge connector that
 | |
| 	    carries the data to and from the drive.  This cable is radially
 | |
| 	    connected, so each drive has its own direct connection to the
 | |
| 	    controller.</para>
 | |
| 	      
 | |
| 	  <para>To the best of my knowledge PC ESDI controllers are limited to
 | |
| 	    using a maximum of 2 drives per controller.  This is compatibility
 | |
| 	    feature(?) left over from the WD1003 standard that reserves only a
 | |
| 	    single bit for device addressing.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Device addressing</title>
 | |
| 	  
 | |
| 	  <para>On each command cable a maximum of 7 devices and 1 controller
 | |
| 	    can be present.  To enable the controller to uniquely  identify
 | |
| 	    which drive it addresses, each ESDI device is equipped with
 | |
| 	    jumpers or switches to select the devices address.</para>
 | |
| 	      
 | |
| 	  <para>On PC type controllers the first drive is set to address 0,
 | |
| 	    the second disk to address 1.  <emphasis>Always make
 | |
| 	      sure</emphasis> you set each disk to an unique address! So, on a
 | |
| 	    PC with its two drives/controller maximum the first drive is drive
 | |
| 	    0, the second is drive 1.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Termination</title>
 | |
| 	  
 | |
| 	  <para>The daisy chained command cable (the 34 pin cable remember?)
 | |
| 	    needs to be terminated at the last drive on the chain.  For this
 | |
| 	    purpose ESDI drives come with a termination resistor network that
 | |
| 	    can be removed or disabled by a jumper when it is not used.</para>
 | |
| 	  
 | |
| 	  <para>So, one and <emphasis>only</emphasis> one drive, the one at
 | |
| 	    the farthest end of the command cable has its terminator
 | |
| 	    installed/enabled.  The controller automatically terminates the
 | |
| 	    other end of the cable.  Please note that this implies that the
 | |
| 	    controller must be  at one end of the cable and
 | |
| 	    <emphasis>not</emphasis> in the middle.</para>
 | |
| 	</sect3>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Using ESDI disks with FreeBSD</title>
 | |
| 
 | |
| 	<para>Why is ESDI such a pain to get working in the first
 | |
| 	  place?</para>
 | |
| 
 | |
| 	<para>People who tried ESDI disks with FreeBSD are known to have
 | |
| 	  developed a profound sense of frustration.  A combination of factors
 | |
| 	  works against you to produce effects that are hard to understand
 | |
| 	  when you have never seen them before.</para>
 | |
| 	    
 | |
| 	<para>This has also led to the popular legend ESDI and FreeBSD is a
 | |
| 	  plain NO-GO.  The following sections try to list all the pitfalls
 | |
| 	  and  solutions.</para>
 | |
| 	    
 | |
| 	<sect3>
 | |
| 	  <title>ESDI speed variants</title>
 | |
| 	  
 | |
| 	  <para>As briefly mentioned before, ESDI comes in two speed flavors.
 | |
| 	    The older drives and controllers use a 10 Mbits/second data
 | |
| 	    transfer rate.  Newer stuff uses 15 Mbits/second.</para>
 | |
| 	      
 | |
| 	  <para>It is not hard to imagine that 15 Mbits/second drive cause
 | |
| 	    problems on controllers laid out for 10 Mbits/second.  As always,
 | |
| 	    consult your controller <emphasis>and</emphasis> drive
 | |
| 	    documentation to see if things match.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Stay on track</title>
 | |
| 	  
 | |
| 	  <para>Mainstream ESDI drives use 34 to 36 sectors per track. Most
 | |
| 	    (older) controllers cannot handle more than this  number of
 | |
| 	    sectors.  Newer, higher capacity, drives use higher numbers of
 | |
| 	    sectors per track.  For instance, I own a 670 MB drive that has 54
 | |
| 	    sectors per track.</para>
 | |
| 	      
 | |
| 	  <para>In my case, the controller could not handle this number of
 | |
| 	    sectors.  It proved to work well except that it only used 35
 | |
| 	    sectors on each track.  This meant losing a lot of disk
 | |
| 	    space.</para>
 | |
| 	      
 | |
| 	  <para>Once again, check the documentation of your hardware for more
 | |
| 	    info.  Going out-of-spec like in the example might or might not
 | |
| 	    work.  Give it a try or get another more capable
 | |
| 	    controller.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Hard or soft sectoring</title>
 | |
| 	  
 | |
| 	  <para>Most ESDI drives allow hard or soft sectoring to be selected
 | |
| 	    using a jumper.  Hard sectoring means that the drive will produce
 | |
| 	    a sector pulse on the start of each new sector. The controller
 | |
| 	    uses this pulse to tell when it should start to write or
 | |
| 	    read.</para>
 | |
| 	  
 | |
| 	  <para>Hard sectoring allows a selection of sector size (normally
 | |
| 	    256, 512 or 1024 bytes per formatted sector).  FreeBSD uses 512
 | |
| 	    byte sectors.  The number of sectors per track also varies while
 | |
| 	    still using the same number of bytes per formatted sector.  The
 | |
| 	    number of <emphasis>unformatted</emphasis> bytes per sector
 | |
| 	    varies, dependent on your controller it needs more or less
 | |
| 	    overhead  bytes to work correctly.  Pushing more sectors on a
 | |
| 	    track  of course gives you more usable space, but might give
 | |
| 	    problems if your controller needs more bytes than the  drive
 | |
| 	    offers.</para>
 | |
| 	      
 | |
| 	  <para>In case of soft sectoring, the controller itself determines
 | |
| 	    where to start/stop reading or writing.  For ESDI hard sectoring
 | |
| 	    is the default (at least on everything I came across).  I never
 | |
| 	    felt the urge to try soft sectoring.</para>
 | |
| 	      
 | |
| 	  <para>In general, experiment with sector settings before you install
 | |
| 	    FreeBSD because you need to re-run the low-level format after each
 | |
| 	    change.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Low level formatting</title>
 | |
| 	  
 | |
| 	  <para>ESDI drives need to be low level formatted before they are
 | |
| 	    usable.  A reformat is needed whenever you figgle with the number
 | |
| 	    of sectors/track jumpers or the physical orientation of the drive
 | |
| 	    (horizontal, vertical).  So, first think, then format.  The format
 | |
| 	    time must not be underestimated, for big disks it can take
 | |
| 	    hours.</para>
 | |
| 	      
 | |
| 	  <para>After a low level format, a surface scan is done to find and
 | |
| 	    flag bad sectors.  Most disks have a manufacturer bad block list
 | |
| 	    listed on a piece of paper or adhesive sticker.  In addition, on
 | |
| 	    most disks the list is also written onto the disk.  Please use the
 | |
| 	    manufacturer's list.  It is much easier to remap a defect now than
 | |
| 	    after FreeBSD is installed.</para>
 | |
| 	      
 | |
| 	  <para>Stay away from low-level formatters that mark all sectors of a
 | |
| 	    track as bad as soon as they find one bad sector.  Not only does
 | |
| 	    this waste space, it also and more importantly causes you grief
 | |
| 	    with bad144 (see the section on bad144).</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Translations</title>
 | |
| 	  
 | |
| 	  <para>Translations, although not exclusively a ESDI-only problem,
 | |
| 	    might give you real trouble.  Translations come in multiple
 | |
| 	    flavors.  Most of them  have in common that they attempt to work
 | |
| 	    around the limitations posed upon disk geometries by the original
 | |
| 	    IBM PC/AT design (thanks IBM!).</para>
 | |
| 	      
 | |
| 	  <para>First of all there is the (in)famous 1024 cylinder limit. For
 | |
| 	    a system to be able to boot, the stuff (whatever operating system)
 | |
| 	    must be in the first 1024 cylinders of a disk.  Only 10 bits are
 | |
| 	    available to encode the cylinder number.  For the number of
 | |
| 	    sectors the limit is 64 (0-63).  When you combine the 1024
 | |
| 	    cylinder limit with the 16 head limit (also a design feature) you
 | |
| 	    max out at fairly limited  disk sizes.</para>
 | |
| 	      
 | |
| 	  <para>To work around this problem, the manufacturers of ESDI PC
 | |
| 	    controllers added a BIOS prom extension on their boards.  This
 | |
| 	    BIOS extension handles disk I/O for booting (and for some
 | |
| 	    operating systems <emphasis>all</emphasis> disk I/O) by using
 | |
| 	    translation.  For instance, a big drive might be presented to the
 | |
| 	    system as having 32 heads and 64 sectors/track.  The result is
 | |
| 	    that the number of cylinders is reduced to something below 1024
 | |
| 	    and is therefore usable by the system without problems.  It is
 | |
| 	    noteworthy to know that FreeBSD does not use the BIOS after its
 | |
| 	    kernel has started.  More on this later.</para>
 | |
| 	      
 | |
| 	  <para>A second reason for translations is the fact that most older
 | |
| 	    system BIOSes could only handle drives with 17 sectors per track
 | |
| 	    (the old ST412 standard).  Newer system BIOSes usually have a
 | |
| 	    user-defined drive type (in most cases this is drive type
 | |
| 	    47).</para>
 | |
| 
 | |
| 	  <warning>
 | |
| 	    <para>Whatever you do to translations after reading this document,
 | |
| 	      keep in mind that if you have multiple operating systems on the
 | |
| 	      same disk, all must use the same translation</para>
 | |
| 	  </warning>
 | |
| 	  
 | |
| 	  <para>While on the subject of translations, I have seen one
 | |
| 	    controller type (but there are probably more like this) offer the
 | |
| 	    option to logically split a drive in multiple partitions as a BIOS
 | |
| 	    option.  I had select 1 drive == 1 partition because this
 | |
| 	    controller wrote this info onto the disk.  On power-up it read the
 | |
| 	    info and presented itself to the system based on the info from the
 | |
| 	    disk.</para>
 | |
| 	</sect3>
 | |
| 	    
 | |
| 	<sect3>
 | |
| 	  <title>Spare sectoring</title>
 | |
| 	  
 | |
| 	  <para>Most ESDI controllers offer the possibility to remap bad
 | |
| 	    sectors.  During/after the low-level format of the disk bad
 | |
| 	    sectors are marked as such, and a replacement sector is put in
 | |
| 	    place (logically of course) of the bad one.</para>
 | |
| 	      
 | |
| 	  <para>In most cases the remapping is done by using N-1 sectors on
 | |
| 	    each track for actual data storage, and sector N itself is the
 | |
| 	    spare sector.  N is the total number of sectors physically
 | |
| 	    available on the track.  The idea behind this is that the
 | |
| 	    operating system sees a <quote>perfect</quote> disk without bad sectors.  In
 | |
| 	    the case of FreeBSD this concept is not usable.</para>
 | |
| 	      
 | |
| 	  <para>The problem is that the translation from
 | |
| 	    <emphasis>bad</emphasis> to <emphasis>good</emphasis> is performed
 | |
| 	    by the BIOS of the ESDI controller.  FreeBSD, being a true 32 bit
 | |
| 	    operating system, does not use the BIOS after it has been booted.
 | |
| 	    Instead, it has device drivers that talk directly to the
 | |
| 	    hardware.</para>
 | |
| 	      
 | |
| 	  <para><emphasis>So: do not use spare sectoring, bad block remapping
 | |
| 	      or whatever it may be called by the controller manufacturer when
 | |
| 	      you want to use the disk for FreeBSD.</emphasis></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Bad block handling</title>
 | |
| 	  
 | |
| 	  <para>The preceding section leaves us with a problem.  The
 | |
| 	    controller's bad block handling is not usable and still FreeBSD's
 | |
| 	    filesystems assume perfect media without any flaws. To solve this
 | |
| 	    problem, FreeBSD use the <command>bad144</command> tool.  Bad144
 | |
| 	    (named after a Digital Equipment standard for bad block handling)
 | |
| 	    scans a FreeBSD slice for bad blocks.  Having found these bad
 | |
| 	    blocks, it writes a table with the offending block numbers to the
 | |
| 	    end of the FreeBSD slice.</para>
 | |
| 	      
 | |
| 	  <para>When the disk is in operation, the disk accesses are checked
 | |
| 	    against the table read from the disk.  Whenever a block number is
 | |
| 	    requested that is in the <command>bad144</command> list, a
 | |
| 	    replacement block (also from the end of the FreeBSD slice) is
 | |
| 	    used.  In this way, the <command>bad144</command> replacement
 | |
| 	    scheme presents <quote>perfect</quote> media to the FreeBSD filesystems.</para>
 | |
| 	      
 | |
| 	  <para>There are a number of potential pitfalls associated with the
 | |
| 	    use of <command>bad144</command>.  First of all, the slice cannot
 | |
| 	    have more than 126 bad sectors.  If your drive has a high number
 | |
| 	    of bad sectors, you might need to divide it into multiple FreeBSD
 | |
| 	    slices each containing less than 126 bad sectors.  Stay away from
 | |
| 	    low-level format programs that mark <emphasis>every</emphasis>
 | |
| 	    sector of a track as bad when  they find a flaw on the track.  As
 | |
| 	    you can imagine, the  126 limit is quickly reached when the
 | |
| 	    low-level format is done this way.</para>
 | |
| 	      
 | |
| 	  <para>Second, if the slice contains the root filesystem, the slice
 | |
| 	    should be within the 1024 cylinder BIOS limit.  During the boot
 | |
| 	    process the bad144 list is read using the BIOS and this only
 | |
| 	    succeeds when the list is within the 1024 cylinder limit.</para>
 | |
| 
 | |
| 	  <note>
 | |
| 	    <para>The restriction is not that only the root
 | |
| 	      <emphasis>filesystem</emphasis> must be within the 1024 cylinder
 | |
| 	      limit, but rather the entire <emphasis>slice</emphasis> that
 | |
| 	      contains the root filesystem.</para>
 | |
| 	  </note>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Kernel configuration</title>
 | |
| 	  
 | |
| 	  <para>ESDI disks are handled by the same <literal>wd</literal>driver
 | |
| 	    as IDE and ST412 MFM disks.  The <literal>wd</literal> driver
 | |
| 	    should work for all WD1003 compatible interfaces.</para>
 | |
| 	      
 | |
| 	  <para>Most hardware is jumperable for one of two different I/O
 | |
| 	    address ranges and IRQ lines.  This allows you to have  two wd
 | |
| 	    type controllers in one system.</para>
 | |
| 	  
 | |
| 	  <para>When your hardware allows non-standard strappings, you can use
 | |
| 	    these with FreeBSD as long as you enter the  correct info into the
 | |
| 	    kernel config file.  An example from the kernel config file (they
 | |
| 	    live in <filename>/sys/i386/conf</filename> BTW).</para>
 | |
| 	      
 | |
| 	  <programlisting># First WD compatible controller
 | |
| controller      wdc0    at isa? port "IO_WD1" bio irq 14 vector wdintr
 | |
| disk            wd0     at wdc0 drive 0
 | |
| disk            wd1     at wdc0 drive 1
 | |
| # Second WD compatible controller
 | |
| controller      wdc1    at isa? port "IO_WD2" bio irq 15 vector wdintr
 | |
| disk            wd2     at wdc1 drive 0
 | |
| disk            wd3     at wdc1 drive 1</programlisting>
 | |
| 	</sect3>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Particulars on ESDI hardware</title>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Adaptec 2320 controllers</title>
 | |
| 	  
 | |
| 	  <para>I successfully installed FreeBSD onto a ESDI disk controlled
 | |
| 	    by a ACB-2320.  No other operating system was present on the
 | |
| 	    disk.</para>
 | |
| 	      
 | |
| 	  <para>To do so I low level formatted the disk using
 | |
| 	    <command>NEFMT.EXE</command> (<command>ftp</command>able from
 | |
| 	    <hostid role="fqdn">www.adaptec.com</hostid>) and answered NO to
 | |
| 	    the question whether the disk should be formatted with a spare
 | |
| 	    sector on each track.  The BIOS on the ACD-2320 was disabled.  I
 | |
| 	    used the <literal>free configurable</literal> option in the system
 | |
| 	    BIOS to allow the BIOS to boot it.</para>
 | |
| 	      
 | |
| 	  <para>Before using <command>NEFMT.EXE</command> I tried to format
 | |
| 	    the disk using the ACB-2320 BIOS built-in formatter.  This proved
 | |
| 	    to be a show stopper, because it did not give me an option to
 | |
| 	    disable spare sectoring.  With spare sectoring enabled the FreeBSD
 | |
| 	    installation process broke down on the <command>bad144</command>
 | |
| 	    run.</para>
 | |
| 	      
 | |
| 	  <para>Please check carefully which
 | |
| 	    ACB-232<replaceable>xy</replaceable> variant you have. The
 | |
| 	    <replaceable>x</replaceable> is either <literal>0</literal> or
 | |
| 	    <literal>2</literal>, indicating a controller without or with a
 | |
| 	    floppy controller on board.</para>
 | |
| 	      
 | |
| 	  <para>The <literal>y</literal> is more interesting.  It can either
 | |
| 	    be a blank, a <literal>A-8</literal> or a <literal>D</literal>.  A
 | |
| 	    blank indicates a plain 10 Mbits/second controller.  An
 | |
| 	    <literal>A-8</literal> indicates a 15 Mbits/second controller
 | |
| 	    capable of handling 52 sectors/track.  A <literal>D</literal>
 | |
| 	    means a 15 Mbits/second controller that can also handle drives
 | |
| 	    with > 36 sectors/track (also 52?).</para>
 | |
| 	      
 | |
| 	  <para>All variations should be capable of using 1:1 interleaving.
 | |
| 	    Use 1:1, FreeBSD is fast enough to handle it.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Western Digital WD1007 controllers</title>
 | |
| 	  
 | |
| 	  <para>I successfully installed FreeBSD onto a ESDI disk controlled
 | |
| 	    by a WD1007 controller.  To be precise, it was a WD1007-WA2.
 | |
| 	    Other variations of the WD1007 do exist.</para>
 | |
| 	      
 | |
| 	  <para>To get it to work, I had to disable the sector translation and
 | |
| 	    the WD1007's onboard BIOS.  This implied I could not use the
 | |
| 	    low-level formatter built into this BIOS.  Instead, I grabbed
 | |
| 	    <command>WDFMT.EXE</command> from <hostid
 | |
| 	      role="fqdn">www.wdc.com</hostid> Running this formatted my drive
 | |
| 	    just fine.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Ultrastor U14F controllers</title>
 | |
| 	  
 | |
| 	  <para>According to multiple reports from the net, Ultrastor ESDI
 | |
| 	    boards work OK with FreeBSD.  I lack any further info on
 | |
| 	    particular settings.</para>
 | |
| 	</sect3>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2 id="esdi-further-reading">
 | |
| 	<title>Further reading</title>
 | |
| 	    
 | |
| 	<para>If you intend to do some serious ESDI hacking, you might want to
 | |
| 	  have the official standard at hand:</para>
 | |
| 	    
 | |
| 	<para>The latest ANSI X3T10 committee document is: Enhanced Small
 | |
| 	  Device Interface (ESDI) [X3.170-1990/X3.170a-1991]    [X3T10/792D
 | |
| 	  Rev 11]</para>
 | |
| 		
 | |
| 	<para>On Usenet the newsgroup <ulink
 | |
| 	    url="news:comp.periphs">comp.periphs</ulink> is a noteworthy place
 | |
| 	  to look  for more info.</para>
 | |
| 	    
 | |
| 	<para>The World Wide Web (WWW) also proves to be a very handy info
 | |
| 	  source: For info on Adaptec ESDI controllers see <ulink
 | |
| 	    url="http://www.adaptec.com/"></ulink>. For
 | |
| 	  info on Western Digital controllers see
 | |
| 	  <ulink url="http://www.wdc.com/"></ulink>.</para>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Thanks to...</title>
 | |
| 
 | |
| 	<para>Andrew Gordon for sending me an Adaptec 2320 controller and ESDI
 | |
| 	  disk for testing.</para>
 | |
|       </sect2>
 | |
|     </sect1>
 | |
|     
 | |
|     <sect1 id="scsi">
 | |
|       <title>What is SCSI?</title>
 | |
|       
 | |
|       <para><emphasis>Copyright © 1995, &a.wilko;.  July 6,
 | |
| 	  1996.</emphasis></para>
 | |
| 	  
 | |
|       <para>SCSI is an acronym for Small Computer Systems Interface.  It is an
 | |
| 	ANSI standard that has become one of the leading I/O buses in the
 | |
| 	computer industry.  The foundation of the SCSI standard was laid by
 | |
| 	Shugart Associates (the same guys that gave the world the first mini
 | |
| 	floppy disks) when they introduced the SASI bus (Shugart Associates
 | |
| 	Standard Interface).</para>
 | |
| 	  
 | |
|       <para>After some time an industry effort was started to come to a more
 | |
| 	strict standard allowing devices from different vendors to work
 | |
| 	together.  This effort was recognized in the ANSI SCSI-1 standard.
 | |
| 	The SCSI-1 standard (approximately 1985) is rapidly becoming obsolete.  The
 | |
| 	current standard is SCSI-2 (see <link
 | |
| 	  linkend="scsi-further-reading">Further reading</link>), with SCSI-3
 | |
| 	on the drawing boards.</para>
 | |
| 	  
 | |
|       <para>In addition to a physical interconnection standard, SCSI defines a
 | |
| 	logical (command set) standard to which disk devices must adhere.
 | |
| 	This standard is called the Common Command Set (CCS) and was developed
 | |
| 	more or less in parallel with ANSI SCSI-1. SCSI-2 includes the
 | |
| 	(revised) CCS as part of the standard itself. The commands are
 | |
| 	dependent on the type of device at hand.  It does not make much sense
 | |
| 	of course to define a Write command for a scanner.</para>
 | |
| 	  
 | |
|       <para>The SCSI bus is a parallel bus, which comes in a number of
 | |
| 	variants.  The oldest and most used is an 8 bit wide bus, with
 | |
| 	single-ended signals, carried on 50 wires.  (If you do not know what
 | |
| 	single-ended means, do not worry, that is what this document is all
 | |
| 	about.)  Modern designs also use 16 bit wide buses, with differential
 | |
| 	signals.  This allows transfer speeds of 20Mbytes/second, on cables
 | |
| 	lengths of up to 25 meters.  SCSI-2 allows a maximum bus width of 32
 | |
| 	bits, using an additional cable. Quickly emerging are Ultra SCSI (also
 | |
| 	called Fast-20) and Ultra2 (also called Fast-40).  Fast-20 is 20
 | |
| 	million transfers per second (20 Mbytes/sec on a 8 bit bus), Fast-40
 | |
| 	is 40 million transfers per second (40 Mbytes/sec on a 8 bit bus).
 | |
| 	Most hard drives sold today are single-ended Ultra SCSI (8 or 16
 | |
| 	bits).</para>
 | |
| 	  
 | |
|       <para>Of course the SCSI bus not only has data lines, but also a number
 | |
| 	of control signals.  A very elaborate protocol is part of the standard
 | |
| 	to allow multiple devices to share the bus in an efficient manner.  In
 | |
| 	SCSI-2, the data is always checked using a separate parity line.  In
 | |
| 	pre-SCSI-2 designs parity was optional.</para>
 | |
| 	  
 | |
|       <para>In SCSI-3 even faster bus types are introduced, along with a
 | |
| 	serial SCSI busses that reduces the cabling overhead and allows a
 | |
| 	higher maximum bus length.  You might see names like SSA and
 | |
| 	fibre channel in this context.  None of the serial buses are currently
 | |
| 	in widespread use (especially not in the typical FreeBSD environment).
 | |
| 	For this reason the serial bus types are not discussed any
 | |
| 	further.</para>
 | |
| 	  
 | |
|       <para>As you could have guessed from the description above, SCSI devices
 | |
| 	are intelligent.  They have to be to adhere to the SCSI standard
 | |
| 	(which is over 2 inches thick BTW).  So, for a hard disk drive for
 | |
| 	instance you do not specify a head/cylinder/sector to address a
 | |
| 	particular block, but simply the number of the block you want.
 | |
| 	Elaborate caching schemes, automatic bad block replacement etc are all
 | |
| 	made possible by this <quote>intelligent device</quote> approach.</para>
 | |
| 	  
 | |
|       <para>On a SCSI bus, each possible pair of devices can communicate.
 | |
| 	Whether their function allows this is another matter, but the standard
 | |
| 	does not restrict it.  To avoid signal contention, the 2 devices have
 | |
| 	to arbitrate for the bus before using it.</para>
 | |
| 	  
 | |
|       <para>The philosophy of SCSI is to have a standard that allows
 | |
| 	older-standard devices to work with newer-standard ones.  So, an old
 | |
| 	SCSI-1 device should normally work on a SCSI-2 bus.  I say Normally,
 | |
| 	because it is not absolutely sure that the implementation of an old
 | |
| 	device follows the (old) standard closely enough to be acceptable on a
 | |
| 	new bus.  Modern devices are usually more well-behaved, because the
 | |
| 	standardization has become more strict and is better adhered to by the
 | |
| 	device manufacturers.</para>
 | |
| 	  
 | |
|       <para>Generally speaking, the chances of getting a working set of
 | |
| 	devices on a single bus is better when all the devices are SCSI-2 or
 | |
| 	newer.  This implies that you do not have to dump all your old stuff
 | |
| 	when you get that shiny 80GB disk: I own a system on which a pre-SCSI-1
 | |
| 	disk, a SCSI-2 QIC tape unit, a SCSI-1 helical scan tape unit and 2
 | |
| 	SCSI-1 disks work together quite happily.  From a performance
 | |
| 	standpoint you might want to separate your older and newer (=faster)
 | |
| 	devices however. This is especially advantageous if you have an
 | |
| 	Ultra160 host adapter where you should separate your U160 devices
 | |
| 	from the Fast and Wide SCSI-2 devices.</para>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Components of SCSI</title>
 | |
| 
 | |
| 	<para>As said before, SCSI devices are smart.  The idea is to put the
 | |
| 	  knowledge about intimate hardware details onto the SCSI device
 | |
| 	  itself.  In this way, the host system does not have to worry about
 | |
| 	  things like how many heads a hard disks has, or how many tracks
 | |
| 	  there are on a specific tape device.  If you are curious, the
 | |
| 	  standard specifies commands with which you can query your devices on
 | |
| 	  their hardware particulars.  FreeBSD uses this capability during
 | |
| 	  boot to check out what devices are connected and whether they need
 | |
| 	  any special treatment.</para>
 | |
| 	    
 | |
| 	<para>The advantage of intelligent devices is obvious: the device
 | |
| 	  drivers on the host can be made in a much more generic fashion,
 | |
| 	  there is no longer a need to change (and qualify!) drivers for every
 | |
| 	  odd new device that is introduced.</para>
 | |
| 	    
 | |
| 	<para>For cabling and connectors there is a golden rule: get good
 | |
| 	  stuff.  With bus speeds going up all the time you will save yourself
 | |
| 	  a lot of grief by using good material.</para>
 | |
| 	    
 | |
| 	<para>So, gold plated connectors, shielded cabling, sturdy connector
 | |
| 	  hoods with strain reliefs etc are the way to go. Second golden rule:
 | |
| 	  do no use cables longer than necessary.  I once spent 3 days hunting
 | |
| 	  down a problem with a flaky machine only to discover that shortening
 | |
| 	  the SCSI bus by 1 meter solved the problem.  And the original bus
 | |
| 	  length was well within the SCSI specification.</para>
 | |
|       </sect2>
 | |
| 	  
 | |
|       <sect2>
 | |
| 	<title>SCSI bus types</title>
 | |
| 
 | |
| 	<para>From an electrical point of view, there are two incompatible bus
 | |
| 	  types: single-ended and differential.  This means that there are two
 | |
| 	  different main groups of SCSI devices and controllers, which cannot
 | |
| 	  be mixed on the same bus.  It is possible however to use special
 | |
| 	  converter hardware to transform a single-ended bus into a
 | |
| 	  differential one (and vice versa).  The differences between the bus
 | |
| 	  types are explained in the next sections.</para>
 | |
| 	    
 | |
| 	<para>In lots of SCSI related documentation there is a sort of jargon
 | |
| 	  in use to abbreviate the different bus types.  A small list:</para>
 | |
| 	    
 | |
| 	<itemizedlist>
 | |
| 	  <listitem>
 | |
| 	    <para>FWD:	Fast Wide Differential</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>FND:	Fast Narrow Differential</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>SE:	Single Ended</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>FN:	Fast Narrow</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>etc.</para>
 | |
| 	  </listitem>
 | |
| 	</itemizedlist>
 | |
| 
 | |
| 
 | |
| 	<para>With a minor amount of imagination one can usually imagine what
 | |
| 	  is meant.</para>
 | |
| 	    
 | |
| 	<para>Wide is a bit ambiguous, it can indicate 16 or 32 bit buses. As
 | |
| 	  far as I know, the 32 bit variant is not (yet) in use, so wide
 | |
| 	  normally means 16 bit.</para>
 | |
| 	    
 | |
| 	<para>Fast means that the timing on the bus is somewhat different, so
 | |
| 	  that on a narrow (8 bit) bus 10 Mbytes/sec are possible instead of 5
 | |
| 	  Mbytes/sec for <quote>slow</quote> SCSI.  As discussed before, bus speeds of 20
 | |
| 	  and 40 million transfers/second are also emerging  (Fast-20 == Ultra
 | |
| 	  SCSI and Fast-40 == Ultra2 SCSI).</para>
 | |
| 
 | |
| 	<note>
 | |
| 	  <para>The data lines > 8 are only used for data transfers and
 | |
| 	    device addressing.  The transfers of commands and status messages
 | |
| 	    etc are only performed on the lowest 8 data lines. The standard
 | |
| 	    allows narrow devices to operate on a wide bus. The usable bus
 | |
| 	    width is negotiated between the devices.  You have to watch your
 | |
| 	    device addressing closely when mixing wide and narrow.</para>
 | |
| 	</note>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Single ended buses</title>
 | |
| 	  
 | |
| 	  <para>A single-ended SCSI bus uses signals that are either 5 Volts
 | |
| 	    or 0 Volts (indeed, TTL levels) and are relative to a COMMON
 | |
| 	    ground reference.  A singled ended 8 bit SCSI bus has
 | |
| 	    approximately 25 ground lines, who are all tied to a single <quote>rail</quote>
 | |
| 	    on all devices.  A standard single ended bus has a maximum length
 | |
| 	    of 6 meters.  If the same bus is used with fast-SCSI devices, the
 | |
| 	    maximum length allowed drops to 3 meters.  Fast-SCSI means that
 | |
| 	    instead of 5Mbytes/sec the bus allows 10Mbytes/sec
 | |
| 	    transfers.</para>
 | |
| 	      
 | |
| 	  <para>Fast-20 (Ultra SCSI) and Fast-40 allow for 20 and 40 million
 | |
| 	    transfers/second respectively.  So, F20 is 20 Mbytes/second on a 8
 | |
| 	    bit bus, 40 Mbytes/second on a 16 bit bus etc.  For F20 the max
 | |
| 	    bus length is 1.5 meters, for F40 it becomes 0.75 meters.  Be
 | |
| 	    aware that F20 is pushing  the limits quite a bit, so you will
 | |
| 	    quickly find out if your SCSI bus is electrically sound.</para>
 | |
| 
 | |
| 	  <note>
 | |
| 	    <para>If some devices on your bus use <quote>fast</quote> to communicate your
 | |
| 	      bus must adhere to the length restrictions for fast
 | |
| 	      buses!</para>
 | |
| 	  </note>
 | |
| 	  
 | |
| 	  <para>It is obvious that with the newer fast-SCSI devices the bus
 | |
| 	    length can become a real bottleneck.  This is why the differential
 | |
| 	    SCSI bus was introduced in the SCSI-2 standard.</para>
 | |
| 	      
 | |
| 	  <para>For connector pinning and connector types please refer to the
 | |
| 	    SCSI-2 standard (see <link linkend="scsi-further-reading">Further
 | |
| 	      reading</link>) itself, connectors etc are listed there in
 | |
| 	    painstaking detail.</para>
 | |
| 	  
 | |
| 	  <para>Beware of devices using non-standard cabling.  For instance
 | |
| 	    Apple uses a 25pin D-type connecter (like the one on serial ports
 | |
| 	    and parallel printers).  Considering that the official SCSI bus
 | |
| 	    needs 50 pins you can imagine the use of this connector needs some
 | |
| 	    <quote>creative cabling</quote>.  The reduction of the number of ground wires
 | |
| 	    they used is a bad idea, you better stick to 50 pins cabling  in
 | |
| 	    accordance with the SCSI standard.  For Fast-20 and 40 do not even
 | |
| 	    think about buses like this.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Differential buses</title>
 | |
| 	  
 | |
| 	  <para>A differential SCSI bus has a maximum length of 25 meters.
 | |
| 	    Quite a difference from the 3 meters for a single-ended fast-SCSI
 | |
| 	    bus.  The idea behind differential signals is that each bus signal
 | |
| 	    has its own return wire.  So, each signal is carried on a
 | |
| 	    (preferably twisted) pair of wires.  The voltage difference
 | |
| 	    between these two wires determines whether the signal is asserted
 | |
| 	    or de-asserted.  To a certain extent the voltage difference
 | |
| 	    between ground and the signal wire pair is not relevant (do not
 | |
| 	    try 10 kVolts though).</para>
 | |
| 	      
 | |
| 	  <para>It is beyond the scope of this document to explain why this
 | |
| 	    differential idea is so much better.  Just accept that
 | |
| 	    electrically seen the use of differential signals gives a much
 | |
| 	    better noise margin.  You will normally find differential buses in
 | |
| 	    use for inter-cabinet connections.  Because of the lower cost
 | |
| 	    single ended is mostly used for shorter buses like inside
 | |
| 	    cabinets.</para>
 | |
| 	      
 | |
| 	  <para>There is nothing that stops you from using differential stuff
 | |
| 	    with FreeBSD, as long as you use a controller that has device
 | |
| 	    driver support in FreeBSD.  As an example, Adaptec marketed the
 | |
| 	    AHA1740 as a single ended board, whereas the AHA1744 was
 | |
| 	    differential.  The software interface to the host is identical for
 | |
| 	    both.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Terminators</title>
 | |
| 	  
 | |
| 	  <para>Terminators in SCSI terminology are resistor networks that are
 | |
| 	    used to get a correct impedance matching.  Impedance matching is
 | |
| 	    important to get clean signals on the bus, without reflections or
 | |
| 	    ringing.  If you once made a long distance telephone call on a bad
 | |
| 	    line you probably know what reflections are.  With 20Mbytes/sec
 | |
| 	    traveling over your SCSI bus, you do not want signals echoing
 | |
| 	    back.</para>
 | |
| 	      
 | |
| 	  <para>Terminators come in various incarnations, with more or less
 | |
| 	    sophisticated designs.  Of course, there are internal and external
 | |
| 	    variants.  Many SCSI devices come with a number of sockets in
 | |
| 	    which a number of resistor networks can (must be!) installed.  If
 | |
| 	    you remove terminators from a device, carefully store them.  You
 | |
| 	    will need them when you ever decide to reconfigure your SCSI bus.
 | |
| 	    There is enough variation in even these simple tiny things to make
 | |
| 	    finding the exact replacement a frustrating business.  There are
 | |
| 	    also SCSI devices that have a single jumper to enable or disable a
 | |
| 	    built-in terminator. There are special terminators you can stick
 | |
| 	    onto a flat cable bus.  Others look like external connectors, or a
 | |
| 	    connector hood without a cable.  So, lots of choice as you can
 | |
| 	    see.</para>
 | |
| 	      
 | |
| 	  <para>There is much debate going on if and when you should switch
 | |
| 	    from simple resistor (passive) terminators to active terminators.
 | |
| 	    Active terminators contain slightly more elaborate circuit to give
 | |
| 	    cleaner bus signals.  The general consensus seems to be that the
 | |
| 	    usefulness of active termination increases when you have long
 | |
| 	    buses and/or fast devices.  If you ever have problems with your
 | |
| 	    SCSI buses you might consider trying an active terminator.  Try to
 | |
| 	    borrow one first, they reputedly are quite expensive.</para>
 | |
| 	      
 | |
| 	  <para>Please keep in mind that terminators for differential and
 | |
| 	    single-ended buses are not identical.  You should <emphasis>not
 | |
| 	      mix</emphasis> the two variants.</para>
 | |
| 	      
 | |
| 	  <para>OK, and now where should you install your terminators? This is
 | |
| 	    by far the most misunderstood part of SCSI.  And it is by far the
 | |
| 	    simplest.  The rule is: <emphasis>every single line on the SCSI
 | |
| 	      bus has 2 (two) terminators, one at each end of the
 | |
| 	      bus.</emphasis> So, two and not one or three or whatever.  Do
 | |
| 	    yourself a favor and stick to this rule.  It will save you endless
 | |
| 	    grief, because wrong termination has the potential to introduce
 | |
| 	    highly mysterious bugs.  (Note the <quote>potential</quote> here;
 | |
| 	    the nastiest part is that it may or may not work.)</para>
 | |
| 	      
 | |
| 	  <para>A common pitfall is to have an internal (flat) cable in a
 | |
| 	    machine and also an external cable attached to the controller. It
 | |
| 	    seems almost everybody forgets to remove the terminators from the
 | |
| 	    controller.  The terminator must now be on the last external
 | |
| 	    device, and not on the controller! In general, every
 | |
| 	    reconfiguration of a SCSI bus must pay attention to this.</para>
 | |
| 
 | |
| 	  <note>
 | |
| 	    <para>Termination is to be done on a per-line basis.  This means
 | |
| 	      if you have both narrow and wide buses connected to the same
 | |
| 	      host adapter, you need to enable termination on the higher 8
 | |
| 	      bits of the bus on the adapter (as well as the last devices on
 | |
| 	      each bus, of course).</para>
 | |
| 	      </note>
 | |
| 	      
 | |
| 	  <para>What I did myself is remove all terminators from my SCSI
 | |
| 	    devices and controllers.  I own a couple of external terminators,
 | |
| 	    for both the Centronics-type external cabling and for the internal
 | |
| 	    flat cable connectors.  This makes reconfiguration much
 | |
| 	    easier.</para>
 | |
| 	      
 | |
| 	  <para>On modern devices, sometimes integrated terminators are used.
 | |
| 	    These things are special purpose integrated circuits that can be
 | |
| 	    enabled or disabled with a control pin.  It is not necessary to
 | |
| 	    physically remove them from a device.  You may find them on newer
 | |
| 	    host adapters, sometimes they are software configurable, using
 | |
| 	    some sort of setup tool.  Some will even auto-detect the cables
 | |
| 	    attached to the connectors and automatically set up the
 | |
| 	    termination as necessary.  At any rate, consult your
 | |
| 	    documentation!</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Terminator power</title>
 | |
| 	  
 | |
| 	  <para>The terminators discussed in the previous chapter need power
 | |
| 	    to operate properly.  On the SCSI bus, a line is dedicated to this
 | |
| 	    purpose.  So, simple huh?</para>
 | |
| 	      
 | |
| 	  <para>Not so.  Each device can provide its own terminator power to
 | |
| 	    the terminator sockets it has on-device.  But if you have external
 | |
| 	    terminators, or when the device supplying the terminator power to
 | |
| 	    the SCSI bus line is switched off you are in trouble.</para>
 | |
| 	      
 | |
| 	  <para>The idea is that initiators (these are devices that initiate
 | |
| 	    actions on the bus, a discussion follows) must supply terminator
 | |
| 	    power.  All SCSI devices are allowed (but not required) to supply
 | |
| 	    terminator power.</para>
 | |
| 	      
 | |
| 	  <para>To allow for un-powered devices on a bus, the terminator power
 | |
| 	    must be supplied to the bus via a diode.  This prevents the
 | |
| 	    backflow of current to un-powered devices.</para>
 | |
| 	      
 | |
| 	  <para>To prevent all kinds of nastiness, the terminator power is
 | |
| 	    usually fused.  As you can imagine, fuses might blow.  This can,
 | |
| 	    but does not have to, lead to a non functional bus.  If multiple
 | |
| 	    devices supply terminator power, a single blown fuse will not put
 | |
| 	    you out of business.  A single supplier with a blown fuse
 | |
| 	    certainly will.  Clever external terminators sometimes have a  LED
 | |
| 	    indication that shows whether terminator power is present.</para>
 | |
| 	      
 | |
| 	  <para>In newer designs auto-restoring fuses that <quote>reset</quote> themselves
 | |
| 	    after some time are sometimes used.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Device addressing</title>
 | |
| 	  
 | |
| 	  <para>Because the SCSI bus is, ehh, a bus there must be a way to
 | |
| 	    distinguish or address the different devices connected to
 | |
| 	    it.</para>
 | |
| 	      
 | |
| 	  <para>This is done by means of the SCSI or target ID.  Each device
 | |
| 	    has a unique target ID.  You can select the ID to which a device
 | |
| 	    must respond using a set of jumpers, or a dip switch, or something
 | |
| 	    similar.  Some SCSI host adapters let you change the target ID
 | |
| 	    from the boot menu.  (Yet some others will not let you change the
 | |
| 	    ID from 7.)  Consult the documentation of your device for more
 | |
| 	    information.</para>
 | |
| 	  
 | |
| 	  <para>Beware of multiple devices configured to use the same ID.
 | |
| 	    Chaos normally reigns in this case.  A pitfall is that one of the
 | |
| 	    devices sharing the same ID sometimes even manages to answer to
 | |
| 	    I/O requests!</para>
 | |
| 	      
 | |
| 	  <para>For an 8 bit bus, a maximum of 8 targets is possible.  The
 | |
| 	    maximum is 8 because the selection is done bitwise using the 8
 | |
| 	    data lines on the bus.  For wide buses this increases to the
 | |
| 	    number of data lines (usually 16).</para>
 | |
| 
 | |
| 	  <note>
 | |
| 	    <para>A narrow SCSI device can not communicate with a SCSI device
 | |
| 	      with a target ID larger than 7.  This means it is generally not
 | |
| 	      a good idea to move your SCSI host adapter's target ID to
 | |
| 	      something higher than 7 (or your CDROM will stop
 | |
| 	      working).</para>
 | |
| 	  </note>
 | |
| 	  
 | |
| 	  <para>The higher the SCSI target ID, the higher the priority the
 | |
| 	    devices has.  When it comes to arbitration between devices that
 | |
| 	    want to use the bus at the same time, the device that has the
 | |
| 	    highest SCSI ID will win.  This also means that the SCSI host
 | |
| 	    adapter usually uses target ID 7.  Note however that the lower 8
 | |
| 	    IDs have higher priorities than the higher 8 IDs on a wide-SCSI
 | |
| 	    bus.  Thus, the order of target IDs is: [7 6 .. 1 0 15 14 .. 9 8]
 | |
| 	    on a wide-SCSI system.  (If you are wondering why the lower 8
 | |
| 	    have higher priority, read the previous paragraph for a
 | |
| 	    hint.)</para>
 | |
| 	      
 | |
| 	  <para>For a further subdivision, the standard allows for Logical
 | |
| 	    Units or LUNs for short.  A single target ID may have multiple
 | |
| 	    LUNs.  For example, a tape device including a tape changer may
 | |
| 	    have LUN 0 for the tape device itself, and LUN 1 for the tape
 | |
| 	    changer.  In this way, the host system can address each of the
 | |
| 	    functional units of the tape changer as desired.</para>
 | |
| 	</sect3>
 | |
| 	    
 | |
| 	<sect3>
 | |
| 	  <title>Bus layout</title>
 | |
| 	  
 | |
| 	  <para>SCSI buses are linear.  So, not shaped like Y-junctions, star
 | |
| 	    topologies, rings, cobwebs or whatever else people might want to
 | |
| 	    invent.  One of the most common mistakes is for people with
 | |
| 	    wide-SCSI host adapters to connect devices on all three connecters
 | |
| 	    (external connector, internal wide connector, internal narrow
 | |
| 	    connector).  Do not do that.  It may appear to work if you are
 | |
| 	    really lucky, but I can almost guarantee that your system will
 | |
| 	    stop functioning at the most unfortunate moment (this is also
 | |
| 	    known as <quote>Murphy's law</quote>).</para>
 | |
| 	      
 | |
| 	  <para>You might notice that the terminator issue discussed earlier
 | |
| 	    becomes rather hairy if your bus is not linear.  Also, if you have
 | |
| 	    more connectors than devices on your internal SCSI cable, make
 | |
| 	    sure you attach devices on connectors on both ends instead of
 | |
| 	    using the connectors in the middle and let one or both ends
 | |
| 	    dangle.  This will screw up the termination of the bus.</para>
 | |
| 	      
 | |
| 	  <para>The electrical characteristics, its noise margins and
 | |
| 	    ultimately the reliability of it all are tightly related to linear
 | |
| 	    bus rule.</para>
 | |
| 	  
 | |
| 	  <para><emphasis>Stick to the linear bus rule!</emphasis></para>
 | |
| 	</sect3>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Using SCSI with FreeBSD</title>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>About translations, BIOSes and magic...</title>
 | |
| 	  
 | |
| 	  <para>As stated before, you should first make sure that you have a
 | |
| 	    electrically sound bus.</para>
 | |
| 	      
 | |
| 	  <para>When you want to use a SCSI disk on your PC as boot disk, you
 | |
| 	    must aware of some quirks related to PC BIOSes.  The PC BIOS in
 | |
| 	    its first incarnation used a low level physical interface to the
 | |
| 	    hard disk.  So, you had to tell the BIOS (using a setup tool or a
 | |
| 	    BIOS built-in setup) how your disk physically looked like.  This
 | |
| 	    involved stating number of heads, number of cylinders, number of
 | |
| 	    sectors per track, obscure things like precompensation and reduced
 | |
| 	    write current cylinder etc.</para>
 | |
| 	      
 | |
| 	  <para>One might be inclined to think that since SCSI disks are smart
 | |
| 	    you can forget about this.  Alas, the arcane setup issue is still
 | |
| 	    present today.  The system BIOS needs to know how to access your
 | |
| 	    SCSI disk with the head/cyl/sector method in order to load the
 | |
| 	    FreeBSD kernel during boot.</para>
 | |
| 	      
 | |
| 	  <para>The SCSI host adapter or SCSI controller you have put in your
 | |
| 	    AT/EISA/PCI/whatever bus to connect your disk therefore has its
 | |
| 	    own on-board BIOS.  During system startup, the SCSI BIOS takes
 | |
| 	    over the hard disk interface routines from the system BIOS.  To
 | |
| 	    fool the system BIOS, the system setup is normally set to No hard
 | |
| 	    disk present.  Obvious, is it not?</para>
 | |
| 	      
 | |
| 	  <para>The SCSI BIOS itself presents to the system a so called
 | |
| 	    <emphasis>translated</emphasis> drive.  This means that a fake
 | |
| 	    drive table is constructed that allows the PC to boot the drive.
 | |
| 	    This translation is often (but not always) done using a pseudo
 | |
| 	    drive with 64 heads and 32 sectors per track.  By varying the
 | |
| 	    number of cylinders, the SCSI BIOS adapts to the actual drive
 | |
| 	    size.  It is useful to note that 32 * 64 / 2 = the size of your
 | |
| 	    drive in megabytes.  The division by 2 is to get from disk blocks
 | |
| 	    that are normally 512 bytes in size to Kbytes.</para>
 | |
| 	      
 | |
| 	  <para>Right.  All is well now?! No, it is not.  The system BIOS has
 | |
| 	    another quirk you might run into.  The number of cylinders of a
 | |
| 	    bootable hard disk cannot be greater than 1024.  Using the
 | |
| 	    translation above, this is a show-stopper for disks greater than 1
 | |
| 	    GB.  With disk capacities going up all the time this is causing
 | |
| 	    problems.</para>
 | |
| 	      
 | |
| 	  <para>Fortunately, the solution is simple: just use another
 | |
| 	    translation, e.g. with 128 heads instead of 32.  In most cases new
 | |
| 	    SCSI BIOS versions are available to upgrade older SCSI host
 | |
| 	    adapters.  Some newer adapters have an option, in the form of a
 | |
| 	    jumper or software setup selection, to switch the translation the
 | |
| 	    SCSI BIOS uses.</para>
 | |
| 	      
 | |
| 	  <para>It is very important that <emphasis>all</emphasis> operating
 | |
| 	    systems on the disk use the <emphasis>same translation</emphasis>
 | |
| 	    to get the right idea about where to find the relevant partitions.
 | |
| 	    So, when installing FreeBSD you must answer any questions about
 | |
| 	    heads/cylinders etc using the translated values your host adapter
 | |
| 	    uses.</para>
 | |
| 	      
 | |
| 	  <para>Failing to observe the translation issue might lead to
 | |
| 	    un-bootable systems or operating systems overwriting each others
 | |
| 	    partitions.  Using fdisk you should be able to see all
 | |
| 	    partitions.</para>
 | |
| 	      
 | |
| 	  <para>You might have heard some talk of <quote>lying</quote> devices?
 | |
| 	    Older FreeBSD kernels used to report the geometry of SCSI disks
 | |
| 	    when booting.  An example from one of my systems:</para>
 | |
| 	      
 | |
| 	  <screen>aha0 targ 0 lun 0: <MICROP 1588-15MB1057404HSP4>
 | |
| da0: 636MB (1303250 total sec), 1632 cyl, 15 head, 53 sec, bytes/sec 512</screen>
 | |
| 
 | |
| 	  <para>Newer kernels usually do not report this information.
 | |
| 	    e.g.</para>
 | |
| 
 | |
| 	  <screen>(bt0:0:0): "SEAGATE ST41651 7574" type 0 fixed SCSI 2
 | |
| da0(bt0:0:0): Direct-Access 1350MB (2766300 512 byte sectors)</screen>
 | |
| 		
 | |
| 	  <para>Why has this changed?</para>
 | |
| 	      
 | |
| 	  <para>This info is retrieved from the SCSI disk itself.  Newer disks
 | |
| 	    often use a technique called zone bit recording.  The idea is that
 | |
| 	    on the outer cylinders of the drive there is more space so more
 | |
| 	    sectors per track can be put on them.  This results in disks that
 | |
| 	    have more tracks on outer cylinders than on the inner cylinders
 | |
| 	    and, last but not least, have more capacity.  You can imagine that
 | |
| 	    the value reported by the drive when inquiring about the geometry
 | |
| 	    now becomes suspect at best, and nearly always misleading.  When
 | |
| 	    asked for a geometry, it is nearly always better to supply the
 | |
| 	    geometry used by the BIOS, or <emphasis>if the BIOS is never going
 | |
| 	      to know about this disk</emphasis>, (e.g. it is not a booting
 | |
| 	    disk) to supply a fictitious geometry that is convenient.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>SCSI subsystem design</title>
 | |
| 	  
 | |
| 	  <para>FreeBSD uses a layered SCSI subsystem.  For each different
 | |
| 	    controller card a device driver is written.  This driver knows all
 | |
| 	    the intimate details about the hardware it controls.  The driver
 | |
| 	    has a interface to the upper layers of the SCSI subsystem through
 | |
| 	    which it receives its commands and reports back any status.</para>
 | |
| 	      
 | |
| 	  <para>On top of the card drivers there are a number of more generic
 | |
| 	    drivers for a class of devices.  More specific: a driver for tape
 | |
| 	    devices (abbreviation: sa, for serial access),
 | |
| 	    magnetic disks (da, for direct access), CDROMs (cd) etc.
 | |
| 	    In case you are wondering where you can find this stuff, it all
 | |
| 	    lives in <filename>/sys/cam/scsi</filename>.  See the man pages in
 | |
| 	    section 4 for more details.</para>
 | |
| 	      
 | |
| 	  <para>The multi level design allows a decoupling of low-level bit
 | |
| 	    banging and more high level stuff.  Adding support for another
 | |
| 	    piece of hardware is a much more manageable problem.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Kernel configuration</title>
 | |
| 	  
 | |
| 	  <para>Dependent on your hardware, the kernel configuration file must
 | |
| 	    contain one or more lines describing your host adapter(s).  This
 | |
| 	    includes I/O addresses, interrupts etc. Consult the manual page for
 | |
| 	    your adapter driver to get more info. Apart from that, check out
 | |
| 	    <filename>/sys/i386/conf/LINT</filename> for an overview of a
 | |
| 	    kernel config file.  <filename>LINT</filename> contains every
 | |
| 	    possible option you can dream of.  It does
 | |
| 	    <emphasis>not</emphasis> imply <filename>LINT</filename> will
 | |
| 	    actually get you to a working kernel at all.</para>
 | |
| 	  
 | |
| 	  <para>Although it is probably stating the obvious: the kernel config
 | |
| 	    file should reflect your actual hardware setup.  So, interrupts,
 | |
| 	    I/O addresses etc must match the kernel config file.  During
 | |
| 	    system boot messages will be displayed to indicate whether the
 | |
| 	    configured hardware was actually found.</para>
 | |
| 
 | |
| 	  <note>
 | |
| 	    <para>Note that most of the EISA/PCI drivers (namely
 | |
| 	      <devicename>ahb</devicename>, <devicename>ahc</devicename>,
 | |
| 	      <devicename>ncr</devicename> and <devicename>amd</devicename>
 | |
| 	      will automatically obtain the correct parameters from the host
 | |
| 	      adapters themselves at boot time; thus, you just need to write,
 | |
| 	      for instance, <literal>controller ahc0</literal>.</para>
 | |
| 	  </note>
 | |
| 	  
 | |
| 	  <para>An example loosely based on the FreeBSD 2.2.5-Release kernel
 | |
| 	    config  file <filename>LINT</filename> with some added comments
 | |
| 	    (between []):</para>
 | |
| 	      
 | |
| 	  <programlisting># SCSI host adapters: `aha', `ahb', `aic', `bt', `nca'
 | |
| #
 | |
| # aha: Adaptec 154x
 | |
| # ahb: Adaptec 174x
 | |
| # ahc: Adaptec 274x/284x/294x
 | |
| # aic: Adaptec 152x and sound cards using the Adaptec AIC-6360 (slow!)
 | |
| # amd: AMD 53c974 based SCSI cards (e.g., Tekram DC-390 and 390T)
 | |
| # bt: Most Buslogic controllers
 | |
| # nca: ProAudioSpectrum cards using the NCR 5380 or Trantor T130
 | |
| # ncr: NCR/Symbios 53c810/815/825/875 etc based SCSI cards
 | |
| # uha: UltraStore 14F and 34F
 | |
| # sea: Seagate ST01/02 8 bit controller (slow!)
 | |
| # wds: Western Digital WD7000 controller (no scatter/gather!).
 | |
| #
 | |
| 
 | |
| [For an Adaptec AHA274x/284x/294x/394x etc controller]
 | |
| controller	ahc0
 | |
| 
 | |
| [For an NCR/Symbios 53c875 based controller]
 | |
| controller	ncr0
 | |
| 
 | |
| [For an Ultrastor adapter]
 | |
| controller	uha0	at isa? port "IO_UHA0" bio irq ? drq 5 vector uhaintr
 | |
| 
 | |
| # Map SCSI buses to specific SCSI adapters
 | |
| controller	scbus0	at ahc0
 | |
| controller	scbus2	at ncr0
 | |
| controller	scbus1  at uha0
 | |
| 
 | |
| # The actual SCSI devices
 | |
| disk da0 at scbus0 target 0 unit 0	[SCSI disk 0 is at scbus 0, LUN 0]
 | |
| disk da1 at scbus0 target 1             [implicit LUN 0 if omitted]
 | |
| disk da2 at scbus1 target 3             [SCSI disk on the uha0]
 | |
| disk da3 at scbus2 target 4             [SCSI disk on the ncr0]
 | |
| tape sa1 at scbus0 target 6             [SCSI tape at target 6]
 | |
| device cd0 at scbus?                    [the first ever CDROM found, no wiring]</programlisting>
 | |
| 	      
 | |
| 	  <para>The example above tells the kernel to look for a ahc (Adaptec
 | |
| 	    274x) controller, then for an NCR/Symbios board, and so on.  The
 | |
| 	    lines following the controller specifications  tell the kernel to
 | |
| 	    configure specific devices but <emphasis>only</emphasis> attach
 | |
| 	    them when they match the target ID and LUN specified on the
 | |
| 	    corresponding bus.</para>
 | |
| 	      
 | |
| 	  <para>Wired down devices get <quote>first shot</quote> at the unit
 | |
| 	    numbers so the first non <quote>wired down</quote> device, is
 | |
| 	    allocated the unit number  one greater than the highest
 | |
| 	    <quote>wired down</quote> unit number for that kind of device.  So,
 | |
| 	    if you had a SCSI tape at target ID 2 it would be configured as
 | |
| 	    sa2, as the tape at target ID 6 is wired down to unit number
 | |
| 	    1.</para>
 | |
| 
 | |
| 	  <note>
 | |
| 	    <para>Wired down devices need not be found to get their unit
 | |
| 	      number.  The unit number for a wired down device is reserved for
 | |
| 	      that device, even if it is turned off at boot time.  This allows
 | |
| 	      the device to be turned on and brought on-line at a later time,
 | |
| 	      without rebooting.  Notice that a device's unit number has
 | |
| 	      <emphasis>no</emphasis> relationship with its target ID on  the
 | |
| 	      SCSI bus.</para>
 | |
| 	  </note>
 | |
| 	  
 | |
| 	  <para>Below is another example of a kernel config file as used by
 | |
| 	    FreeBSD version < 2.0.5.  The difference with the first example
 | |
| 	    is that devices are not <quote>wired down</quote>.  <quote>Wired
 | |
| 	    down</quote> means that you specify which SCSI target belongs to
 | |
| 	    which device.</para>
 | |
| 	      
 | |
| 	  <para>A kernel built to the config file below will attach  the first
 | |
| 	    SCSI disk it finds to da0, the second disk to da1 etc. If you ever
 | |
| 	    removed or added a disk, all other devices of the same type (disk
 | |
| 	    in this case) would <quote>move around</quote>.  This implies you have to
 | |
| 	    change <filename>/etc/fstab</filename> each time.</para>
 | |
| 	      
 | |
| 	  <para>Although the old style still works, you  are
 | |
| 	    <emphasis>strongly</emphasis> recommended to use this new feature.
 | |
| 	    It will save you a lot of grief whenever you shift your hardware
 | |
| 	    around on the SCSI buses.  So, when you re-use your old trusty
 | |
| 	    config file after upgrading from a pre-FreeBSD2.0.5.R system check
 | |
| 	    this out.</para>
 | |
| 	  
 | |
| 	  <programlisting>[driver for Adaptec 174x]
 | |
| controller      ahb0 at isa? bio irq 11 vector ahbintr
 | |
| 
 | |
| [for Adaptec 154x]
 | |
| controller      aha0    at isa? port "IO_AHA0" bio irq 11 drq 5 vector ahaintr
 | |
| 
 | |
| [for Seagate ST01/02]
 | |
| controller      sea0    at isa? bio irq 5 iomem 0xc8000 iosiz 0x2000 vector seaintr
 | |
| 
 | |
| controller      scbus0
 | |
| 
 | |
| device          da0     [support for 4 SCSI harddisks, da0 up da3]
 | |
| device          sa0	[support for 2 SCSI tapes]
 | |
| 
 | |
| [for the CDROM]
 | |
| device          cd0     #Only need one of these, the code dynamically grows</programlisting>
 | |
| 	      
 | |
| 	  <para>Both examples support SCSI disks.  If during boot more devices
 | |
| 	    of a specific type (e.g. da disks) are found than are configured
 | |
| 	    in the booting kernel, the system will simply allocate more
 | |
| 	    devices, incrementing the unit number starting at the last number
 | |
| 	    <quote>wired down</quote>.  If there are no <quote>wired
 | |
| 	    down</quote> devices then counting starts at unit 0.</para>
 | |
| 	      
 | |
| 	  <para>Use <command>man 4 scsi</command> to check for the latest info
 | |
| 	    on the SCSI subsystem.  For more detailed info on host adapter
 | |
| 	    drivers use e.g., <command>man 4 ahc</command> for info on the
 | |
| 	    Adaptec 294x driver.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Tuning your SCSI kernel setup</title>
 | |
| 	  
 | |
| 	  <para>Experience has shown that some devices are slow to respond to
 | |
| 	    INQUIRY commands after a SCSI bus reset (which happens at boot
 | |
| 	    time).  An INQUIRY command is sent by the kernel on boot to see
 | |
| 	    what kind of device (disk, tape, CDROM etc.) is connected to a
 | |
| 	    specific target ID.  This process is called device probing by the
 | |
| 	    way.</para>
 | |
| 	      
 | |
| 	  <para>To work around the <quote>slow response</quote> problem, FreeBSD allows a
 | |
| 	    tunable delay time before the SCSI devices are probed following a
 | |
| 	    SCSI bus reset.  You can set this delay time in your kernel
 | |
| 	    configuration file using a line like:</para>
 | |
| 	      
 | |
| 	  <programlisting>options         SCSI_DELAY=15         #Be pessimistic about Joe SCSI device</programlisting>
 | |
| 
 | |
| 	  <para>This line sets the delay time to 15 seconds.  On my own system
 | |
| 	    I had to use 3 seconds minimum to get my trusty old CDROM drive
 | |
| 	    to be recognized.  Start with a high value (say 30 seconds or so)
 | |
| 	    when you have problems  with device recognition.  If this helps,
 | |
| 	    tune it back until it just stays working.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="scsi-rogue-devices">
 | |
| 	  <title>Rogue SCSI devices</title>
 | |
| 	      
 | |
| 	  <para>Although the SCSI standard tries to be complete and concise,
 | |
| 	    it is a complex standard and implementing things correctly is no
 | |
| 	    easy task.  Some vendors do a better job then others.</para>
 | |
| 	      
 | |
| 	  <para>This is exactly where the <quote>rogue</quote> devices come
 | |
| 	    into view. Rogues are devices that are recognized by the FreeBSD
 | |
| 	    kernel as behaving slightly (...) non-standard.  Rogue devices are
 | |
| 	    reported by the kernel when booting.  An example for two of my
 | |
| 	    cartridge tape units:</para>
 | |
| 	  
 | |
| 	  <screen>Feb 25 21:03:34 yedi /kernel: ahb0 targ 5 lun 0: <TANDBERG TDC 3600       -06:>
 | |
| Feb 25 21:03:34 yedi /kernel: sa0: Tandberg tdc3600 is a known rogue
 | |
| 
 | |
| Mar 29 21:16:37 yedi /kernel: aha0 targ 5 lun 0: <ARCHIVE VIPER 150  21247-005>
 | |
| Mar 29 21:16:37 yedi /kernel: sa1: Archive  Viper 150 is a known rogue </screen>
 | |
| 	      
 | |
| 	  <para>For instance, there are devices that respond to all LUNs on a
 | |
| 	    certain target ID, even if they are actually only one device.  It
 | |
| 	    is easy to see that the kernel might be fooled into believing that
 | |
| 	    there are 8 LUNs at that particular target ID. The confusion this
 | |
| 	    causes is left as an exercise to the reader.</para>
 | |
| 	      
 | |
| 	  <para>The SCSI subsystem of FreeBSD recognizes devices with bad
 | |
| 	    habits by looking at the INQUIRY response they send when probed.
 | |
| 	    Because the INQUIRY response also includes the version number of
 | |
| 	    the device  firmware, it is even possible that for different
 | |
| 	    firmware versions different workarounds are used. See e.g.
 | |
| 	    <filename>/sys/cam/scsi/scsi_sa.c</filename> and
 | |
| 	    <filename>/sys/cam/scsi/scsi_all.c</filename> for more info on how
 | |
| 	    this is done.</para>
 | |
| 	      
 | |
| 	  <para>This scheme works fine, but keep in mind that it of course
 | |
| 	    only works for devices that are known to be weird.  If you are the
 | |
| 	    first to connect your bogus Mumbletech SCSI CDROM you might be
 | |
| 	    the one that has to define which workaround is needed.</para>
 | |
| 	      
 | |
| 	  <para>After you got your Mumbletech working, please send the
 | |
| 	    required workaround to the FreeBSD development team for inclusion
 | |
| 	    in the next release of FreeBSD.  Other Mumbletech owners will be
 | |
| 	    grateful  to you.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Multiple LUN devices</title>
 | |
| 	  
 | |
| 	  <para>In some cases you come across devices that use multiple
 | |
| 	    logical units (LUNs) on a single SCSI ID.  In most cases FreeBSD
 | |
| 	    only probes devices for LUN 0.  An example are so called bridge
 | |
| 	    boards that connect 2 non-SCSI hard disks to a SCSI bus (e.g. an
 | |
| 	    Emulex MD21 found in old Sun systems).</para>
 | |
| 	      
 | |
| 	  <para>This means that any devices with LUNs != 0 are not normally
 | |
| 	    found during device probe on system boot.  To work around this
 | |
| 	    problem you must add an appropriate entry in /sys/cam/scsi
 | |
| 	    and rebuild your kernel.</para>
 | |
| 	      
 | |
| 	  <para>Look for a struct that is initialized like below:
 | |
| 	    (FIXME: which file? Do these entries still exist in this form
 | |
|             now that we use CAM?)</para>
 | |
| 
 | |
| 	  <programlisting>{
 | |
|         T_DIRECT, T_FIXED, "MAXTOR", "XT-4170S", "B5A",
 | |
|         "mx1", SC_ONE_LU
 | |
| }</programlisting>
 | |
| 	      
 | |
| 	  <para>For your Mumbletech BRIDGE2000 that has more than one LUN, acts
 | |
| 	    as a SCSI disk and has firmware revision 123 you would add
 | |
| 	    something like:</para>
 | |
| 	      
 | |
| 	  <programlisting>{
 | |
|         T_DIRECT, T_FIXED, "MUMBLETECH", "BRIDGE2000", "123",
 | |
|         "da", SC_MORE_LUS
 | |
| }</programlisting>
 | |
| 	      
 | |
| 	  <para>The kernel on boot scans the inquiry data it receives against
 | |
| 	    the table and acts accordingly.  See the source for more
 | |
| 	    info.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Tagged command queuing</title>
 | |
| 	  
 | |
| 	  <para>Modern SCSI devices, particularly magnetic disks,
 | |
| 	    support what is called tagged command queuing (TCQ).</para>
 | |
| 	  
 | |
| 	  <para>In a nutshell, TCQ allows the device to have multiple I/O
 | |
| 	    requests outstanding at the same time.  Because the device is
 | |
| 	    intelligent, it can optimize its operations (like head
 | |
| 	    positioning) based on its own request queue.  On  SCSI devices
 | |
| 	    like RAID (Redundant Array of Independent Disks) arrays the TCQ
 | |
| 	    function is indispensable to take advantage of the device's
 | |
| 	    inherent parallelism.</para>
 | |
| 	      
 | |
| 	  <para>Each I/O request is uniquely identified by a <quote>tag</quote>
 | |
| 	    (hence the name tagged command queuing) and this tag is used by
 | |
| 	    FreeBSD to see which I/O in the device drivers queue is reported
 | |
| 	    as complete by the device.</para>
 | |
| 	      
 | |
| 	  <para>It should be noted however that TCQ requires device driver
 | |
| 	    support and that some devices implemented it <quote>not quite
 | |
| 	    right</quote> in their firmware.  This problem bit me once, and it
 | |
| 	    leads to highly mysterious problems.  In such cases, try to
 | |
| 	    disable TCQ.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Bus-master host adapters</title>
 | |
| 	  
 | |
| 	  <para>Most, but not all, SCSI host adapters are bus mastering
 | |
| 	    controllers.  This means that they can do I/O on their own without
 | |
| 	    putting load onto the host CPU for data movement.</para>
 | |
| 	      
 | |
| 	  <para>This is of course an advantage for a multitasking operating
 | |
| 	    system like FreeBSD.  It must be noted however that there might be
 | |
| 	    some rough edges.</para>
 | |
| 	      
 | |
| 	  <para>For instance an Adaptec 1542 controller can be set to use
 | |
| 	    different transfer speeds on the host bus (ISA or AT in this
 | |
| 	    case).  The controller is settable to different rates because not
 | |
| 	    all motherboards can handle the higher speeds.  Problems like
 | |
| 	    hang-ups, bad data etc might be the result of using a higher data
 | |
| 	    transfer rate then your motherboard can stomach.</para>
 | |
| 	      
 | |
| 	  <para>The solution is of course obvious: switch to a lower data
 | |
| 	    transfer rate and try if that works better.</para>
 | |
| 	      
 | |
| 	  <para>In the case of a Adaptec 1542, there is an option that can be
 | |
| 	    put into the kernel config file to allow dynamic determination of
 | |
| 	    the right, read: fastest feasible, transfer rate.  This option is
 | |
| 	    disabled by default:</para>
 | |
| 	      
 | |
| 	  <programlisting>options        "TUNE_1542"             #dynamic tune of bus DMA speed</programlisting>
 | |
| 	      
 | |
| 	  <para>Check the manual pages for the host adapter that you use.  Or
 | |
| 	    better still, use the ultimate documentation (read: driver
 | |
| 	    source).</para>
 | |
| 	</sect3>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Tracking down problems</title>
 | |
| 
 | |
| 	<para>The following list is an attempt to give a guideline for the
 | |
| 	  most common SCSI problems and their solutions.  It is by no means
 | |
| 	  complete.</para>
 | |
| 	    
 | |
| 	<itemizedlist>
 | |
| 	  <listitem>
 | |
| 	    <para>Check for loose connectors and cables.</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>Check and double check the location and number of your
 | |
| 	      terminators.</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>Check if your bus has at least one supplier of terminator
 | |
| 	      power (especially with external terminators.</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>Check if no double target IDs are used.</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>Check if all devices to be used are powered up.</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>Make a minimal bus config with as little devices as
 | |
| 	      possible.</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>If possible, configure your host adapter to use slow bus
 | |
| 	      speeds.</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>Disable tagged command queuing to make things as simple as
 | |
| 	      possible (for a NCR host adapter based system see man
 | |
| 	      ncrcontrol)</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>If you can compile a kernel, make one with the
 | |
| 	      <literal>SCSIDEBUG</literal> option, and try accessing the
 | |
| 	      device with debugging turned on for that device.  If your device
 | |
| 	      does not even probe at startup, you may have to define the
 | |
| 	      address of the device that is failing, and the desired debug
 | |
| 	      level in <filename>/sys/cam/cam_debug.h</filename>. If it
 | |
| 	      probes but just does not work, you can use the
 | |
| 	      &man.camcontrol.8; command to dynamically set a debug level to
 | |
| 	      it in a running kernel (if <literal>CAMDEBUG</literal> is
 | |
| 	      defined).  This will give you <emphasis>copious</emphasis>
 | |
| 	      debugging output with which to confuse the gurus. See
 | |
| 	      <command>man camcontrol</command> for more exact information.  Also
 | |
| 	      look at <command>man 4 pass</command>.</para>
 | |
| 	  </listitem>
 | |
| 	</itemizedlist>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2 id="scsi-further-reading">
 | |
| 	<title>Further reading</title>
 | |
| 
 | |
| 	<para>If you intend to do some serious SCSI hacking, you might want to
 | |
| 	  have the official standard at hand:</para>
 | |
| 	    
 | |
| 	<para>Approved American National Standards can be purchased from
 | |
| 	  ANSI at
 | |
| 	  
 | |
| 	  <address>
 | |
| 	    <otheraddr>13th Floor</otheraddr>
 | |
| 	    <street>11 West 42nd Street</street>
 | |
| 	    <city>New York</city>
 | |
| 	    <state>NY</state> <postcode>10036</postcode>
 | |
| 	    Sales Dept: <phone>(212) 642-4900</phone>
 | |
| 	  </address>
 | |
| 	</para>
 | |
| 
 | |
| 	<para>You can also buy many ANSI
 | |
| 	  standards and most committee draft documents from Global
 | |
| 	  Engineering Documents,
 | |
| 
 | |
| 	  <address>
 | |
| 	    <street>15 Inverness Way East</street>
 | |
| 	    <city>Englewood</city>
 | |
| 	    <state>CO</state>, <postcode>80112-5704</postcode>
 | |
| 	    Phone: <phone>(800) 854-7179</phone>
 | |
| 	    Outside USA and Canada: <phone>(303) 792-2181</phone>
 | |
| 	    Fax: <fax>(303) 792- 2192</fax>
 | |
| 	  </address>
 | |
| 	</para>
 | |
| 
 | |
| 	<para>Many X3T10 draft documents are available electronically on the
 | |
| 	  SCSI BBS (719-574-0424) and on the <hostid
 | |
| 	    role="fqdn">ncrinfo.ncr.com</hostid> anonymous FTP site.</para>
 | |
| 	    
 | |
| 	<para>Latest X3T10 committee documents are:</para>
 | |
| 
 | |
| 	<itemizedlist>
 | |
| 	  <listitem>
 | |
| 	    <para>AT Attachment (ATA or IDE) [X3.221-1994]
 | |
| 	      (<emphasis>Approved</emphasis>)</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>ATA Extensions (ATA-2) [X3T10/948D Rev 2i]</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>Enhanced Small Device Interface (ESDI)
 | |
| 	      [X3.170-1990/X3.170a-1991]
 | |
| 	      (<emphasis>Approved</emphasis>)</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>Small Computer System Interface — 2 (SCSI-2)
 | |
| 	      [X3.131-1994] (<emphasis>Approved</emphasis>)</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para>SCSI-2 Common Access Method Transport and SCSI Interface
 | |
| 	      Module (CAM)  [X3T10/792D Rev 11]</para>
 | |
| 	  </listitem>
 | |
| 	</itemizedlist>
 | |
| 
 | |
| 	<para>Other publications that might provide you with additional
 | |
| 	  information are:</para>
 | |
| 
 | |
| 	<itemizedlist>
 | |
| 	  <listitem>
 | |
| 	    <para><quote>SCSI: Understanding the Small Computer System
 | |
| 	      Interface</quote>, written by NCR  Corporation.  Available from:
 | |
| 	      Prentice Hall, Englewood Cliffs, NJ, 07632 Phone: (201) 767-5937
 | |
| 	      ISBN 0-13-796855-8</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para><quote>Basics of SCSI</quote>, a SCSI tutorial written by
 | |
| 	      Ancot Corporation Contact Ancot for availability information at:
 | |
| 	      Phone: (415) 322-5322  Fax: (415) 322-0455</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para><quote>SCSI Interconnection Guide Book</quote>, an AMP
 | |
| 	      publication (dated 4/93, Catalog  65237) that lists the various
 | |
| 	      SCSI connectors and suggests cabling schemes.  Available from
 | |
| 	      AMP at (800) 522-6752 or (717) 564-0100</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para><quote>Fast Track to SCSI</quote>, A Product Guide written by
 | |
| 	      Fujitsu.  Available from: Prentice Hall, Englewood Cliffs, NJ,
 | |
| 	      07632 Phone: (201) 767-5937 ISBN 0-13-307000-X</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para><quote>The SCSI Bench Reference</quote>, <quote>The SCSI
 | |
| 	      Encyclopedia</quote>, and the <quote>SCSI Tutor</quote>, ENDL
 | |
| 	      Publications, 14426 Black Walnut Court, Saratoga CA, 95070
 | |
| 	      Phone: (408) 867-6642</para>
 | |
| 	  </listitem>
 | |
| 	  
 | |
| 	  <listitem>
 | |
| 	    <para><quote>Zadian SCSI Navigator</quote> (quick ref. book) and
 | |
| 	      <quote>Discover the Power of SCSI</quote>  (First book along with
 | |
| 	      a one-hour video and tutorial book), Zadian Software, Suite 214,
 | |
| 	      1210 S. Bascom Ave., San Jose, CA 92128, (408) 293-0800</para>
 | |
| 	  </listitem>
 | |
| 	</itemizedlist>
 | |
| 
 | |
| 	<para>On Usenet the newsgroups <ulink
 | |
| 	    url="news:comp.periphs.scsi">comp.periphs.scsi</ulink> and <ulink
 | |
| 	    url="news:comp.periphs">comp.periphs</ulink> are noteworthy places
 | |
| 	  to look for more info.  You can also find the <ulink
 | |
| 	  url="http://scsifaq.org:9080/scsi_faq/scsifaq.html">SCSI-FAQ</ulink>
 | |
| 	  there, which is posted periodically.</para>
 | |
| 
 | |
| 	<para>Most major SCSI device and host adapter suppliers operate FTP
 | |
| 	  sites and/or BBS systems.  They may be valuable sources of
 | |
| 	  information about the devices you own.</para>
 | |
|       </sect2>
 | |
|     </sect1>
 | |
|     
 | |
|     <sect1 id="hw-storage-controllers">
 | |
|       <title>* Disk/tape controllers</title>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>* SCSI</title>
 | |
| 
 | |
| 	<para></para>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>* IDE</title>
 | |
| 
 | |
| 	<para></para>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>* Floppy</title>
 | |
| 
 | |
| 	<para></para>
 | |
|       </sect2>
 | |
|     </sect1>
 | |
|     
 | |
|     <sect1>
 | |
|       <title>Hard drives</title>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>SCSI hard drives</title>
 | |
| 
 | |
| 	<para><emphasis>Contributed by &a.asami;.  17 February
 | |
| 	    1998.</emphasis></para>
 | |
| 	    
 | |
| 	<para>As mentioned in the <link linkend="scsi">SCSI</link> section,
 | |
| 	  virtually all SCSI hard drives sold today are SCSI-2 compliant and
 | |
| 	  thus will work fine as long as you connect them to a supported SCSI
 | |
| 	  host adapter.  Most problems people encounter are either due to
 | |
| 	  badly designed cabling (cable too long, star topology, etc.),
 | |
| 	  insufficient termination, or defective parts. Please refer to the
 | |
| 	  <link linkend="scsi">SCSI</link> section first if your SCSI hard
 | |
| 	  drive is not working.  However, there are a couple of things you may
 | |
| 	  want to take into account before you purchase SCSI hard drives for
 | |
| 	  your system.</para>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Rotational speed</title>
 | |
| 	  
 | |
| 	  <para>Rotational speeds of SCSI drives sold today range from around
 | |
| 	    4,500RPM to 15,000RPM.  Most of them are either 7,200RPM or
 | |
| 	    10,000RPM, with 15,000RPM becoming affordable (June 2002).
 | |
| 	    Even though the 10,000RPM drives can generally transfer
 | |
| 	    data faster, they run considerably hotter than their 7,200RPM
 | |
| 	    counterparts.  A large fraction of today's disk drive malfunctions
 | |
| 	    are heat-related.  If you do not have very good cooling in your PC
 | |
| 	    case, you may want to stick with 7,200RPM or slower drives.</para>
 | |
| 	      
 | |
| 	  <para>Note that newer drives, with higher areal recording densities,
 | |
| 	    can deliver much more bits per rotation than older ones.  Today's
 | |
| 	    top-of-line 7,200RPM drives can sustain a throughput comparable to
 | |
| 	    10,000RPM drives of one or two model generations ago.  The number
 | |
| 	    to find on the spec sheet for bandwidth is <quote>internal data
 | |
| 	    (or transfer) rate</quote>.  It is usually in megabits/sec so
 | |
| 	    divide it by 8 and you will get the rough approximation of how much
 | |
| 	    megabytes/sec you can get out of the drive.</para>
 | |
| 	      
 | |
| 	  <para>(If you are a speed maniac and want a 15,000RPM drive for your
 | |
| 	    cute little PC, be my guest; however, those drives become
 | |
| 	    extremely hot.  Do not even think about it if you do not have a fan
 | |
| 	    blowing air <emphasis>directly at</emphasis> the drive or a
 | |
| 	    properly ventilated disk enclosure.)</para>
 | |
| 	      
 | |
| 	  <para>Obviously, the latest 15,000RPM drives and 10,000RPM drives can
 | |
| 	    deliver more data than the latest 7,200RPM drives, so if absolute
 | |
| 	    bandwidth is the necessity for your applications, you have little
 | |
| 	    choice but to get the faster drives.  Also, if you need low
 | |
| 	    latency, faster drives are better; not only do they usually have
 | |
| 	    lower average seek times, but also the rotational delay is one
 | |
| 	    place where slow-spinning drives can never beat a faster one.
 | |
| 	    (The average rotational latency is half the time it takes to
 | |
| 	    rotate the drive once; thus, it is 2 milliseconds for 15,000RPM,
 | |
| 	    3ms for 10,000RPM
 | |
| 	    drives, 4.2ms for 7,200RPM drives and 5.6ms for 5,400RPM drives.)
 | |
| 	    Latency is seek time plus rotational delay. Make sure you
 | |
| 	    understand whether you need low latency or more accesses per
 | |
| 	    second, though; in the latter case (e.g., news servers), it may
 | |
| 	    not be optimal to purchase one big fast drive.  You can achieve
 | |
| 	    similar or even better results by using the ccd (concatenated
 | |
| 	    disk) driver to create a striped disk array out of multiple slower
 | |
| 	    drives for comparable overall cost.</para>
 | |
| 	      
 | |
| 	  <para>Make sure you have adequate air flow around the drive,
 | |
| 	    especially if you are going to use a fast-spinning drive.  You
 | |
| 	    generally need at least 1/2” (1.25cm) of spacing above and below a
 | |
| 	    drive.  Understand how the air flows through your PC case.  Most
 | |
| 	    cases have the power supply suck the air out of the back.  See
 | |
| 	    where the air flows in, and put the drive where it will have the
 | |
| 	    largest volume of cool air flowing around it. You may need to seal
 | |
| 	    some unwanted holes or add a new fan for effective cooling.</para>
 | |
| 	      
 | |
| 	  <para>Another consideration is noise.  Many 10,000 or faster drives
 | |
| 	    generate a high-pitched whine which is quite unpleasant to most
 | |
| 	    people.  That, plus the extra fans often required for cooling, may
 | |
| 	    make 10,000 or faster drives unsuitable for some office and home
 | |
| 	    environments.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Form factor</title>
 | |
| 	  
 | |
| 	  <para>Most SCSI drives sold today are of 3.5” form factor.  They
 | |
| 	    come in two different heights; 1.6” (<quote>half-height</quote>) or
 | |
| 	    1” (<quote>low-profile</quote>).  The half-height drive is the same
 | |
| 	    height as a CDROM drive.  However, do not forget the spacing rule
 | |
| 	    mentioned in the previous section.  If you have three standard
 | |
| 	    3.5” drive bays, you will not be able to put three half-height
 | |
| 	    drives in there (without frying them, that is).</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Interface</title>
 | |
| 	  
 | |
| 	  <para>The majority of SCSI hard drives sold today are Ultra,
 | |
| 	    Ultra-wide, or Ultra160 SCSI. As of this writing (June 2002),
 | |
| 	    the first Ultra320 host adapters and devices become available.
 | |
| 	    The maximum bandwidth of Ultra SCSI is 20MB/sec,
 | |
| 	    and Ultra-wide SCSI is 40MB/sec. Ultra160 can transfer 160MB/sec
 | |
| 	    and Ultra320 can transfer 320MB/sec.  There is no difference in max
 | |
| 	    cable length between Ultra and Ultra-wide; however, the more
 | |
| 	    devices you have on the same bus, the sooner you will start having
 | |
| 	    bus integrity problems.  Unless you have a well-designed disk
 | |
| 	    enclosure, it is not easy to make more than 5 or 6 Ultra SCSI
 | |
| 	    drives work on a single bus.</para>
 | |
| 	      
 | |
| 	  <para>On the other hand, if you need to connect many drives, going
 | |
| 	    for Fast-wide SCSI may not be a bad idea.  That will have the same
 | |
| 	    max bandwidth as Ultra (narrow) SCSI, while electronically it is
 | |
| 	    much easier to get it <quote>right</quote>.  My advice would be: if
 | |
| 	    you want to connect many disks, get wide or Ultra160 SCSI drives;
 | |
|         they usually
 | |
| 	    cost a little more but it may save you down the road.  (Besides,
 | |
| 	    if you can not afford the cost difference, you should not be building
 | |
| 	    a disk array.)</para>
 | |
| 	      
 | |
| 	  <para>There are two variant of wide SCSI drives; 68-pin and 80-pin
 | |
| 	    SCA (Single Connector Attach).  The SCA drives do not have a
 | |
| 	    separate 4-pin power connector, and also read the SCSI ID settings
 | |
| 	    through the 80-pin connector.  If you are really serious about
 | |
| 	    building a large storage system, get SCA drives and a good SCA
 | |
| 	    enclosure (dual power supply with at least one extra fan).  They
 | |
| 	    are more electronically sound than 68-pin counterparts because
 | |
| 	    there is no <quote>stub</quote> of the SCSI bus inside the disk
 | |
| 	    canister as in arrays built from 68-pin drives.  They are easier
 | |
| 	    to install too (you just need to screw the drive in the canister,
 | |
| 	    instead of trying to squeeze in your fingers in a tight place to
 | |
| 	    hook up all the little cables (like the SCSI ID and disk activity
 | |
| 	    LED lines).</para>
 | |
| 	</sect3>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>* IDE hard drives</title>
 | |
| 
 | |
| 	<para></para>
 | |
|       </sect2>
 | |
|     </sect1>
 | |
|     
 | |
|     <sect1>
 | |
|       <title>Tape drives</title>
 | |
|       
 | |
|       <para><emphasis>Contributed by &a.jmb;.  2 July
 | |
| 	  1996.</emphasis></para>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>General tape access commands</title>
 | |
| 
 | |
| 	<para>&man.mt.1; provides generic access to the tape drives.  Some of
 | |
| 	  the more common commands are <command>rewind</command>,
 | |
| 	  <command>erase</command>, and <command>status</command>.  See the
 | |
| 	    &man.mt.1; manual page for a detailed description.</para>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Controller Interfaces</title>
 | |
| 
 | |
| 	<para>There are several different interfaces that support tape drives.
 | |
| 	  The interfaces are SCSI, IDE, Floppy and Parallel Port. A wide
 | |
| 	  variety of tape drives are available for these interfaces.
 | |
| 	  Controllers are discussed in <link
 | |
| 	    linkend="hw-storage-controllers">Disk/tape
 | |
| 	    controllers</link>.</para>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>SCSI drives</title>
 | |
| 
 | |
| 	<para>The &man.st.4; driver provides support for 8mm (Exabyte), 4mm
 | |
| 	  (DAT: Digital Audio Tape), QIC (Quarter-Inch Cartridge), DLT
 | |
| 	  (Digital Linear Tape), QIC Mini cartridge and 9-track (remember the
 | |
| 	  big reels that you see spinning in Hollywood computer rooms) tape
 | |
| 	  drives.  See the &man.st.4; manual page for a detailed
 | |
| 	  description.</para>
 | |
| 
 | |
| 	<para>The drives listed below are currently being used by members of
 | |
| 	  the FreeBSD community.  They are not the only drives that will work
 | |
| 	  with FreeBSD.  They just happen to be the ones that we use.</para>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>4mm (DAT: Digital Audio Tape)</title>
 | |
| 	  
 | |
| 	  <para><link linkend="hw-storage-python-28454">Archive Python
 | |
| 	      28454</link></para>
 | |
| 
 | |
| 	  <para><link linkend="hw-storage-python-04687">Archive Python
 | |
| 	      04687</link></para>
 | |
| 	  
 | |
| 	  <para><link linkend="hw-storage-hp1533a">HP C1533A</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-hp1534a">HP C1534A</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-hp35450a">HP 35450A</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-hp35470a">HP 35470A</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-hp35480a">HP 35480A</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-sdt5000">SDT-5000</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-wangtek6200">Wangtek
 | |
| 	      6200</link></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>8mm (Exabyte)</title>
 | |
| 	  
 | |
| 	  <para><link linkend="hw-storage-exb8200">EXB-8200</link></para>
 | |
| 	  
 | |
| 	  <para><link linkend="hw-storage-exb8500">EXB-8500</link></para>
 | |
| 	  
 | |
| 	  <para><link linkend="hw-storage-exb8505">EXB-8505</link></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>QIC (Quarter-Inch Cartridge)</title>
 | |
| 	  
 | |
| 	  <para><link linkend="hw-storage-anaconda">Archive Anaconda
 | |
| 	      2750</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-viper60">Archive Viper
 | |
| 	      60</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-viper150">Archive Viper
 | |
| 	      150</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-viper2525">Archive Viper
 | |
| 	      2525</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-tandberg3600">Tandberg TDC
 | |
| 	      3600</link></para>
 | |
| 
 | |
| 	  <para><link linkend="hw-storage-tandberg3620">Tandberg TDC
 | |
| 	      3620</link></para>
 | |
| 	    
 | |
| 	  <para><link linkend="hw-storage-tandberg3800">Tandberg TDC
 | |
| 	      3800</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-tandberg4222">Tandberg TDC
 | |
| 	      4222</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-wangtek5525es">Wangtek
 | |
| 	      5525ES</link></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>DLT (Digital Linear Tape)</title>
 | |
| 	  
 | |
| 	  <para><link linkend="hw-storage-dectz87">Digital TZ87</link></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Mini-Cartridge</title>
 | |
| 	  
 | |
| 	  <para><link linkend="hw-storage-ctms3200">Conner CTMS
 | |
| 	      3200</link></para>
 | |
| 	      
 | |
| 	  <para><link linkend="hw-storage-exb2501">Exabyte 2501</link></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3>
 | |
| 	  <title>Autoloaders/Changers</title>
 | |
| 	  
 | |
| 	  <para><link linkend="hw-storage-hp1553a">Hewlett-Packard HP C1553A
 | |
| 	      Autoloading DDS2</link></para>
 | |
| 	</sect3>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>* IDE drives</title>
 | |
| 
 | |
| 	<para></para>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Floppy drives</title>
 | |
| 
 | |
| 	<para><link linkend="hw-storage-conner420r">Conner 420R</link></para>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>* Parallel port drives</title>
 | |
| 
 | |
| 	<para></para>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>Detailed Information</title>
 | |
| 
 | |
| 	<sect3 id="hw-storage-anaconda">
 | |
| 	  <title>Archive Anaconda 2750</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>ARCHIVE
 | |
| 	      ANCDA 2750 28077 -003 type 1 removable SCSI 2</literal></para>
 | |
| 	  
 | |
| 	  <para>This is a QIC tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 1.35GB when using QIC-1350 tapes.  This
 | |
| 	    drive will read and write QIC-150 (DC6150), QIC-250 (DC6250), and
 | |
| 	    QIC-525 (DC6525) tapes as well.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 350kB/s using &man.dump.8;.
 | |
| 	    Rates of 530kB/s have been reported when using
 | |
| 	    Amanda</para>
 | |
| 
 | |
| 	  <para>Production of this drive has been discontinued.</para>
 | |
| 	  
 | |
| 	  <para>The SCSI bus connector on this tape drive is reversed from
 | |
| 	    that on most other SCSI devices.  Make sure that you have enough
 | |
| 	    SCSI cable to twist the cable one-half turn before and after the
 | |
| 	    Archive Anaconda tape drive, or turn your other SCSI devices
 | |
| 	    upside-down.</para>
 | |
| 	  
 | |
| 	  <para>Two kernel code changes are required to use this drive. This
 | |
| 	    drive will not work as delivered.</para>
 | |
| 	      
 | |
| 	  <para>If you have a SCSI-2 controller, short jumper 6. Otherwise,
 | |
| 	    the drive behaves are a SCSI-1 device.  When operating as a SCSI-1
 | |
| 	    device, this drive, <quote>locks</quote> the SCSI bus during some
 | |
| 	    tape operations, including: fsf, rewind, and rewoffl.</para>
 | |
| 	      
 | |
| 	  <para>If you are using the NCR SCSI controllers, patch the file
 | |
| 	    <filename>/usr/src/sys/pci/ncr.c</filename> (as shown below).
 | |
| 	    Build and install a new kernel.</para>
 | |
| 	      
 | |
| 	  <programlisting>*** 4831,4835 ****
 | |
|                 };
 | |
|         
 | |
| !               if (np->latetime>4) {
 | |
|                         /*
 | |
|                         **      Although we tried to wake it up,
 | |
| --- 4831,4836 ----
 | |
|                 };
 | |
| 
 | |
| !               if (np->latetime>1200) {
 | |
|                         /*
 | |
|                         **      Although we tried to wake it up,</programlisting>
 | |
| 	      
 | |
| 	  <para>Reported by: &a.jmb;</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-python-28454">
 | |
| 	  <title>Archive Python 28454</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>ARCHIVE
 | |
| 	      Python 28454-XXX4ASB</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal> <literal>density code 0x8c, 512-byte
 | |
| 	      blocks</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a DDS-1 tape drive.</para>
 | |
| 	      
 | |
| 	  <para>Native capacity is 2.5GB on 90m tapes.</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is XXX.</para>
 | |
| 	  
 | |
| 	  <para>This drive was repackaged by Sun Microsystems as model
 | |
| 	    595-3067.</para>
 | |
| 	      
 | |
| 	  <para>Reported by: Bob Bishop <email>rb@gid.co.uk</email></para>
 | |
| 	  
 | |
| 	  <para>Throughput is in the 1.5 MByte/sec range, however this will
 | |
| 	    drop if the disks and tape drive are on the same SCSI
 | |
| 	    controller.</para>
 | |
| 
 | |
| 	  <para>Reported by: Robert E. Seastrom
 | |
| 	    <email>rs@seastrom.com</email></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-python-04687">
 | |
| 	  <title>Archive Python 04687</title>
 | |
| 
 | |
| 	  <para>The boot message identifier for this drive is <literal>ARCHIVE 
 | |
| 	      Python 04687-XXX 6580</literal> <literal>Removable Sequential
 | |
| 	      Access SCSI-2 device</literal></para>
 | |
| 
 | |
| 	  <para>This is a DAT-DDS-2 drive.</para>
 | |
| 
 | |
| 	  <para>Native capacity is 4GB when using 120m tapes.</para>
 | |
| 
 | |
| 	  <para>This drive supports hardware data compression.  Switch 4
 | |
| 	    controls MRS (Media Recognition System).  MRS tapes have stripes
 | |
| 	    on the transparent leader.  Switch 4 <emphasis>off</emphasis>
 | |
| 	    enables MRS, <emphasis>on</emphasis> disables MRS.</para>
 | |
| 
 | |
| 	  <para>Parity is controlled by switch 5.  Switch 5
 | |
| 	    <emphasis>on</emphasis> to enable parity control.  Compression is
 | |
| 	    enabled with Switch 6 <emphasis>off</emphasis>.  It is possible to 
 | |
| 	    override compression with the <literal>SCSI MODE SELECT</literal>
 | |
| 	    command (see &man.mt.1;).</para>
 | |
| 
 | |
| 	  <para>Data transfer rate is 800kB/s.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-viper60">
 | |
| 	  <title>Archive Viper 60</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>ARCHIVE
 | |
| 	      VIPER 60 21116 -007</literal> <literal>type 1 removable SCSI
 | |
| 	      1</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a QIC tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 60MB.</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is XXX.</para>
 | |
| 	  
 | |
| 	  <para>Production of this drive has been discontinued.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: Philippe Regnauld
 | |
| 	    <email>regnauld@hsc.fr</email></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-viper150">
 | |
| 	  <title>Archive Viper 150</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>ARCHIVE
 | |
| 	      VIPER 150 21531 -004</literal> <literal>Archive Viper 150 is a
 | |
| 	      known rogue</literal> <literal>type 1 removable SCSI
 | |
| 	      1</literal>.  A multitude of firmware revisions exist for this
 | |
| 	    drive.  Your drive may report different numbers (e.g
 | |
| 	    <literal>21247 -005</literal>.</para>
 | |
| 	      
 | |
| 	  <para>This is a QIC tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 150/250MB.  Both 150MB (DC6150) and 250MB
 | |
| 	    (DC6250) tapes have the recording format.  The 250MB tapes are
 | |
| 	    approximately 67% longer than the 150MB tapes.  This drive can
 | |
| 	    read 120MB tapes as well.  It can not write 120MB tapes.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 100kB/s</para>
 | |
| 	  
 | |
| 	  <para>This drive reads and writes DC6150 (150MB) and DC6250 (250MB)
 | |
| 	    tapes.</para>
 | |
| 	      
 | |
| 	  <para>This drives quirks are known and pre-compiled into the SCSI
 | |
| 	    tape device driver (&man.st.4;).</para>
 | |
| 	      
 | |
| 	  <para>Under FreeBSD 2.2-CURRENT, use <command>mt blocksize
 | |
| 	      512</command> to set the blocksize.  (The particular drive had
 | |
| 	    firmware revision 21247 -005.  Other firmware revisions may behave
 | |
| 	    differently) Previous versions of FreeBSD did not have this
 | |
| 	    problem.</para>
 | |
| 	      
 | |
| 	  <para>Production of this drive has been discontinued.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: Pedro A M Vazquez
 | |
| 	    <email>vazquez@IQM.Unicamp.BR</email></para>
 | |
| 	  
 | |
| 	  <para>&a.msmith;</para>
 | |
| 	</sect3>
 | |
| 	    
 | |
| 	<sect3 id="hw-storage-viper2525">
 | |
| 	  <title>Archive Viper 2525</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>ARCHIVE
 | |
| 	      VIPER 2525 25462 -011</literal> <literal>type 1 removable SCSI
 | |
| 	      1</literal></para>
 | |
| 	  
 | |
| 	  <para>This is a QIC tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 525MB.</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is 180kB/s at 90 inches/sec.</para>
 | |
| 	  
 | |
| 	  <para>The drive reads QIC-525, QIC-150, QIC-120 and QIC-24 tapes.
 | |
| 	    Writes QIC-525, QIC-150, and QIC-120.</para>
 | |
| 	      
 | |
| 	  <para>Firmware revisions prior to <literal>25462 -011</literal> are
 | |
| 	    bug ridden and will not function properly.</para>
 | |
| 	  
 | |
| 	  <para>Production of this drive has been discontinued.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-conner420r">
 | |
| 	  <title>Conner 420R</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>Conner
 | |
| 	      tape</literal>.</para>
 | |
| 	      
 | |
| 	  <para>This is a floppy controller, mini cartridge tape drive.</para>
 | |
| 	      
 | |
| 	  <para>Native capacity is XXXX</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is XXX</para>
 | |
| 	  
 | |
| 	  <para>The drive uses QIC-80 tape cartridges.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: Mark Hannon
 | |
| 	    <email>mark@seeware.DIALix.oz.au</email></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-ctms3200">
 | |
| 	  <title>Conner CTMS 3200</title>
 | |
| 	      
 | |
| 	  <para>The boot message identifier for this drive is <literal>CONNER
 | |
| 	      CTMS 3200 7.00</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal>.</para>
 | |
| 	      
 | |
| 	  <para>This is a mini cartridge tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is XXXX</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is XXX</para>
 | |
| 	  
 | |
| 	  <para>The drive uses QIC-3080 tape cartridges.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: Thomas S. Traylor
 | |
| 	    <email>tst@titan.cs.mci.com</email></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-dectz87">
 | |
| 	  <title><ulink
 | |
| 	      url="http://www.digital.com/info/Customer-Update/931206004.txt.html">DEC TZ87</ulink></title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>DEC
 | |
| 	      TZ87 (C) DEC 9206</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal> <literal>density code 0x19</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a DLT tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 10GB.</para>
 | |
| 	  
 | |
| 	  <para>This drive supports hardware data compression.</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is 1.2MB/s.</para>
 | |
| 	  
 | |
| 	  <para>This drive is identical to the Quantum DLT2000.  The drive
 | |
| 	    firmware can be set to emulate several well-known drives,
 | |
| 	    including an Exabyte 8mm drive.</para>
 | |
| 	      
 | |
| 	  <para>Reported by: &a.wilko;</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-exb2501">
 | |
| 	  <title><ulink
 | |
| 	      url="http://www.Exabyte.COM:80/Products/Minicartridge/2501/Rfeatures.html">Exabyte EXB-2501</ulink></title>
 | |
| 	      
 | |
| 	  <para>The boot message identifier for this drive is <literal>EXABYTE
 | |
| 	      EXB-2501</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a mini-cartridge tape drive.</para>
 | |
| 	      
 | |
| 	  <para>Native capacity is 1GB when using MC3000XL
 | |
| 	    mini cartridges.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is XXX</para>
 | |
| 	  
 | |
| 	  <para>This drive can read and write DC2300 (550MB), DC2750 (750MB),
 | |
| 	    MC3000 (750MB), and MC3000XL (1GB) mini cartridges.</para>
 | |
| 	      
 | |
| 	  <para>WARNING: This drive does not meet the SCSI-2 specifications.
 | |
| 	    The drive locks up completely in response to a SCSI MODE_SELECT
 | |
| 	    command unless there is a formatted tape in the drive.  Before
 | |
| 	    using this drive, set the tape blocksize with</para>
 | |
| 	      
 | |
| 	  <screen>&prompt.root; <userinput>mt -f /dev/st0ctl.0 blocksize 1024</userinput></screen>
 | |
| 	      
 | |
| 	  <para>Before using a mini cartridge for the first time, the
 | |
| 	    mini cartridge must be formated.  FreeBSD 2.1.0-RELEASE and
 | |
| 	    earlier:</para>
 | |
| 	      
 | |
| 	  <screen>&prompt.root; <userinput>/sbin/scsi -f /dev/rst0.ctl -s 600 -c "4 0 0 0 0 0"</userinput></screen>
 | |
| 	      
 | |
| 	  <para>(Alternatively, fetch a copy of the
 | |
| 	    <command>scsiformat</command> shell script from FreeBSD
 | |
| 	    2.1.5/2.2.) FreeBSD 2.1.5 and later:</para>
 | |
| 	      
 | |
| 	  <screen>&prompt.root; <userinput>/sbin/scsiformat -q -w /dev/rst0.ctl</userinput></screen>
 | |
| 	      
 | |
| 	  <para>Right now, this drive cannot really be recommended for
 | |
| 	    FreeBSD.</para>
 | |
| 	      
 | |
| 	  <para>Reported by: Bob Beaulieu
 | |
| 	    <email>ez@eztravel.com</email></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-exb8200">
 | |
| 	  <title>Exabyte EXB-8200</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>EXABYTE
 | |
| 	      EXB-8200 252X</literal> <literal>type 1 removable SCSI
 | |
| 	      1</literal></para>
 | |
| 	      
 | |
| 	  <para>This is an 8mm tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 2.3GB.</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is 270kB/s.</para>
 | |
| 	  
 | |
| 	  <para>This drive is fairly slow in responding to the SCSI bus during
 | |
| 	    boot.  A custom kernel may be required (set SCSI_DELAY to 10
 | |
| 	    seconds).</para>
 | |
| 	  
 | |
| 	  <para>There are a large number of firmware configurations for this
 | |
| 	    drive, some have been customized to a particular vendor's
 | |
| 	    hardware.  The firmware can be changed via EPROM
 | |
| 	    replacement.</para>
 | |
| 	      
 | |
| 	  <para>Production of this drive has been discontinued.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: &a.msmith;</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-exb8500">
 | |
| 	  <title>Exabyte EXB-8500</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>EXABYTE
 | |
| 	      EXB-8500-85Qanx0 0415</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal></para>
 | |
| 	      
 | |
| 	  <para>This is an 8mm tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 5GB.</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is 300kB/s.</para>
 | |
| 	      
 | |
| 	  <para>Reported by: Greg Lehey <email>grog@lemis.de</email></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-exb8505">
 | |
| 	  <title><ulink
 | |
| 	      url="http://www.Exabyte.COM:80/Products/8mm/8505XL/Rfeatures.html">Exabyte EXB-8505</ulink></title>
 | |
| 	      
 | |
| 	      <para>The boot message identifier for this drive is
 | |
| 	    <literal>EXABYTE EXB-85058SQANXR1 05B0</literal> <literal>type 1
 | |
| 	      removable SCSI 2</literal></para>
 | |
| 	      
 | |
| 	  <para>This is an 8mm tape drive which supports compression, and is
 | |
| 	    upward compatible with the EXB-5200 and EXB-8500.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 5GB.</para>
 | |
| 	  
 | |
| 	  <para>The drive supports hardware data compression.</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is 300kB/s.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: Glen Foster
 | |
| 	    <email>gfoster@gfoster.com</email></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-hp1533a">
 | |
| 	  <title>Hewlett-Packard HP C1533A</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>HP
 | |
| 	      C1533A 9503</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal>.</para>
 | |
| 	      
 | |
| 	  <para>This is a DDS-2 tape drive.  DDS-2 means hardware data
 | |
| 	    compression and narrower tracks for increased data
 | |
| 	    capacity.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 4GB when using 120m tapes.  This drive
 | |
| 	    supports hardware data compression.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 510kB/s.</para>
 | |
| 	  
 | |
| 	  <para>This drive is used in Hewlett-Packard's SureStore 6000eU and
 | |
| 	    6000i tape drives and C1533A DDS-2 DAT drive.</para>
 | |
| 	  
 | |
| 	  <para>The drive has a block of 8 dip switches.  The proper settings
 | |
| 	    for FreeBSD are: 1 ON; 2 ON; 3 OFF; 4 ON; 5 ON; 6 ON; 7 ON; 8
 | |
| 	    ON.</para>
 | |
| 	  
 | |
| 	  <informaltable frame="none">
 | |
| 	    <tgroup cols="3">
 | |
| 	      <thead>
 | |
| 		<row>
 | |
| 		  <entry>switch 1</entry>
 | |
| 		  <entry>switch 2</entry>
 | |
| 		  <entry>Result</entry>
 | |
| 		</row>
 | |
| 	      </thead>
 | |
| 	      
 | |
| 	      <tbody>
 | |
| 		<row>
 | |
| 		  <entry>On</entry>
 | |
| 		  <entry>On</entry>
 | |
| 		  <entry>Compression enabled at power-on, with host
 | |
| 		    control</entry>
 | |
| 		</row>
 | |
| 		
 | |
| 		<row>
 | |
| 		  <entry>On</entry>
 | |
| 		  <entry>Off</entry>
 | |
| 		  <entry>Compression enabled at power-on, no host
 | |
| 		    control</entry>
 | |
| 		</row>
 | |
| 		
 | |
| 		<row>
 | |
| 		  <entry>Off</entry>
 | |
| 		  <entry>On</entry>
 | |
| 		  <entry>Compression disabled at power-on, with host
 | |
| 		    control</entry>
 | |
| 		</row>
 | |
| 		
 | |
| 		<row>
 | |
| 		  <entry>Off</entry>
 | |
| 		  <entry>Off</entry>
 | |
| 		  <entry>Compression disabled at power-on, no host
 | |
| 		    control</entry>
 | |
| 		</row>
 | |
| 	      </tbody>
 | |
| 	    </tgroup>
 | |
| 	  </informaltable>
 | |
| 	  
 | |
| 	  <para>Switch 3 controls MRS (Media Recognition System).  MRS tapes
 | |
| 	    have stripes on the transparent leader.  These identify the tape
 | |
| 	    as DDS (Digital Data Storage) grade media.  Tapes that do not have
 | |
| 	    the stripes will be treated as write-protected.  Switch 3 OFF
 | |
| 	    enables MRS.  Switch 3 ON disables MRS.</para>
 | |
| 	      
 | |
| 	      <para>See <ulink url="http://www.hp.com/tape/c_intro.html">HP
 | |
| 	      SureStore Tape Products</ulink> and <ulink
 | |
| 	      url="http://www.impediment.com/hp/hp_technical.html">Hewlett-Packard
 | |
| 	      Disk and Tape Technical Information</ulink> for more information
 | |
| 	    on configuring this drive.</para>
 | |
| 	      
 | |
| 	  <para><emphasis>Warning:</emphasis> Quality control on these drives
 | |
| 	    varies greatly.  One FreeBSD core-team member has returned 2 of
 | |
| 	    these drives.  Neither lasted more than 5 months.</para>
 | |
| 	      
 | |
| 	  <para>Reported by: &a.se;</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-hp1534a">
 | |
| 	  <title>Hewlett-Packard HP 1534A</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>HP
 | |
| 	      HP35470A T503</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal> <literal>Sequential-Access density code 0x13,
 | |
| 	      variable blocks</literal>.</para>
 | |
| 	      
 | |
| 	  <para>This is a DDS-1 tape drive.  DDS-1 is the original DAT tape
 | |
| 	    format.</para>
 | |
| 	      
 | |
| 	  <para>Native capacity is 2GB when using 90m tapes.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 183kB/s.</para>
 | |
| 	  
 | |
| 	  <para>The same mechanism is used in Hewlett-Packard's SureStore
 | |
| 	    <ulink url="http://www.dmo.hp.com/tape/sst2000.htm">2000i</ulink>
 | |
| 	    tape drive, C35470A DDS format DAT drive, C1534A DDS format DAT
 | |
| 	    drive and HP C1536A DDS format DAT drive.</para>
 | |
| 	      
 | |
| 	  <para>The HP C1534A DDS format DAT drive has two indicator lights,
 | |
| 	    one green and one amber.  The green one indicates tape action:
 | |
| 	    slow flash during load, steady when loaded, fast flash during
 | |
| 	    read/write operations.  The amber one indicates warnings: slow
 | |
| 	    flash when cleaning is required or tape is nearing the end of its
 | |
| 	    useful life, steady indicates an hard fault.  (factory service
 | |
| 	    required?)</para>
 | |
| 	      
 | |
| 	  <para>Reported by Gary Crutcher
 | |
| 	    <email>gcrutchr@nightflight.com</email></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-hp1553a">
 | |
| 	  <title>Hewlett-Packard HP C1553A Autoloading DDS2</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is "".</para>
 | |
| 	  
 | |
| 	  <para>This is a DDS-2 tape drive with a tape changer.  DDS-2 means
 | |
| 	    hardware data compression and narrower tracks for increased data
 | |
| 	    capacity.</para>
 | |
| 	      
 | |
| 	  <para>Native capacity is 24GB when using 120m tapes.  This drive
 | |
| 	    supports hardware data compression.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 510kB/s (native).</para>
 | |
| 	      
 | |
| 	  <para>This drive is used in Hewlett-Packard's SureStore <ulink
 | |
| 	      url="http://www.dmo.hp.com/tape/sst12000.htm">12000e</ulink>
 | |
| 	    tape drive.</para>
 | |
| 	      
 | |
| 	  <para>The drive has two selectors on the rear panel.  The selector
 | |
| 	    closer to the fan is SCSI id.  The other selector should be set to
 | |
| 	    7.</para>
 | |
| 	      
 | |
| 	  <para>There are four internal switches.  These should be set: 1 ON;
 | |
| 	    2 ON; 3 ON; 4 OFF.</para>
 | |
| 	      
 | |
| 	  <para>At present the kernel drivers do not automatically change
 | |
| 	    tapes at the end of a volume.  This shell script can be used to
 | |
| 	    change tapes:</para>
 | |
| 	      
 | |
| 	  <programlisting>#!/bin/sh
 | |
| PATH="/sbin:/usr/sbin:/bin:/usr/bin"; export PATH
 | |
| 
 | |
| usage()
 | |
| {
 | |
|         echo "Usage: dds_changer [123456ne] raw-device-name
 | |
|         echo "1..6 = Select cartridge"
 | |
|         echo "next cartridge"
 | |
|         echo "eject magazine"
 | |
|         exit 2
 | |
| }
 | |
| 
 | |
| if [ $# -ne 2 ] ; then
 | |
|         usage
 | |
| fi
 | |
| 
 | |
| cdb3=0
 | |
| cdb4=0
 | |
| cdb5=0
 | |
| 
 | |
| case $1 in
 | |
|         [123456])
 | |
|                 cdb3=$1
 | |
|                 cdb4=1
 | |
|                 ;;
 | |
|         n)
 | |
|                 ;;
 | |
|         e)
 | |
|                 cdb5=0x80
 | |
|                 ;;
 | |
|         ?)
 | |
|                 usage
 | |
|                 ;;
 | |
| esac
 | |
| 
 | |
| scsi -f $2 -s 100 -c "1b 0 0 $cdb3 $cdb4 $cdb5"</programlisting>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-hp35450a">
 | |
| 	  <title>Hewlett-Packard HP 35450A</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>HP
 | |
| 	      HP35450A -A C620</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal> <literal>Sequential-Access density code
 | |
| 	      0x13</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a DDS-1 tape drive.  DDS-1 is the original DAT tape
 | |
| 	    format.</para>
 | |
| 	      
 | |
| 	  <para>Native capacity is 1.2GB.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 160kB/s.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: Mark Thompson
 | |
| 	    <email>mark.a.thompson@pobox.com</email></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-hp35470a">
 | |
| 	  <title>Hewlett-Packard HP 35470A</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>HP
 | |
| 	      HP35470A 9 09</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a DDS-1 tape drive.  DDS-1 is the original DAT tape
 | |
| 	    format.</para>
 | |
| 	      
 | |
| 	  <para>Native capacity is 2GB when using 90m tapes.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 183kB/s.</para>
 | |
| 	  
 | |
| 	  <para>The same mechanism is used in Hewlett-Packard's SureStore
 | |
| 	    <ulink url="http://www.dmo.hp.com/tape/sst2000.htm">2000i</ulink>
 | |
| 	    tape drive, C35470A DDS format DAT drive, C1534A DDS format DAT
 | |
| 	    drive, and HP C1536A DDS format DAT drive.</para>
 | |
| 	      
 | |
| 	  <para><emphasis>Warning:</emphasis> Quality control on these drives
 | |
| 	    varies greatly.  One FreeBSD core-team member has returned 5 of
 | |
| 	    these drives.  None lasted more than 9 months.</para>
 | |
| 	      
 | |
| 	  <para>Reported by: David Dawes
 | |
| 	    <email>dawes@rf900.physics.usyd.edu.au</email> (9 09)</para>
 | |
| 	      
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-hp35480a">
 | |
| 	  <title>Hewlett-Packard HP 35480A</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>HP
 | |
| 	      HP35480A 1009</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal> <literal>Sequential-Access density code
 | |
| 	      0x13</literal>.</para>
 | |
| 	      
 | |
| 	  <para>This is a DDS-DC tape drive.  DDS-DC is DDS-1 with hardware
 | |
| 	    data compression.  DDS-1 is the original DAT tape format.</para>
 | |
| 	      
 | |
| 	  <para>Native capacity is 2GB when using 90m tapes.  It cannot handle
 | |
| 	    120m tapes.  This drive supports hardware data compression.
 | |
| 	    Please refer to the section on <link
 | |
| 	      linkend="hw-storage-hp1533a">HP C1533A</link> for the proper
 | |
| 	    switch settings.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 183kB/s.</para>
 | |
| 	  
 | |
| 	  <para>This drive is used in Hewlett-Packard's SureStore <ulink
 | |
| 	      url="http://www.dmo.hp.com/tape/sst5000.htm">5000eU</ulink> and
 | |
| 	    <ulink url="http://www.dmo.hp.com/tape/sst5000.htm">5000i</ulink>
 | |
| 	    tape drives and C35480A DDS format DAT drive..</para>
 | |
| 	      
 | |
| 	  <para>This drive will occasionally hang during a tape eject
 | |
| 	    operation (<command>mt offline</command>). Pressing the front
 | |
| 	    panel button will eject the tape and bring the tape drive back to
 | |
| 	    life.</para>
 | |
| 	      
 | |
| 	  <para>WARNING: HP 35480-03110 only.  On at least two occasions this
 | |
| 	    tape drive when used with FreeBSD 2.1.0, an IBM Server 320 and an
 | |
| 	    2940W SCSI controller resulted in all SCSI disk partitions being
 | |
| 	    lost.  The problem has not be analyzed or resolved at this
 | |
| 	    time.</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-sdt5000">
 | |
| 	  <title><ulink
 | |
| 	      url="http://www.sel.sony.com/SEL/ccpg/storage/tape/t5000.html">Sony SDT-5000</ulink></title>
 | |
| 	      
 | |
| 	  <para>There are at least two significantly different models: one is
 | |
| 	    a DDS-1 and the other DDS-2.  The DDS-1 version is
 | |
| 	    <literal>SDT-5000 3.02</literal>.  The DDS-2 version is
 | |
| 	    <literal>SONY SDT-5000 327M</literal>. The DDS-2 version has a 1MB
 | |
| 	    cache.  This cache is able to keep the tape streaming in almost
 | |
| 	    any circumstances.</para>
 | |
| 	      
 | |
| 	  <para>The boot message identifier for this drive is <literal>SONY
 | |
| 	      SDT-5000 3.02</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal> <literal>Sequential-Access density code
 | |
| 	      0x13</literal></para>
 | |
| 	      
 | |
| 	  <para>Native capacity is 4GB when using 120m tapes.  This drive
 | |
| 	    supports hardware data compression.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is depends upon the model or the drive. The
 | |
| 	    rate is 630kB/s for the <literal>SONY SDT-5000 327M</literal>
 | |
| 	    while compressing the data.  For the <literal>SONY SDT-5000
 | |
| 	      3.02</literal>, the data transfer rate is 225kB/s.</para>
 | |
| 	      
 | |
| 	  <para>In order to get this drive to stream, set the blocksize to 512
 | |
| 	    bytes (<command>mt blocksize 512</command>) reported by Kenneth
 | |
| 	    Merry <email>ken@ulc199.residence.gatech.edu</email>.</para>
 | |
| 	      
 | |
| 	  <para><literal>SONY SDT-5000 327M</literal> information reported by
 | |
| 	    Charles Henrich <email>henrich@msu.edu</email>.</para>
 | |
| 	      
 | |
| 	  <para>Reported by: &a.jmz;</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-tandberg3600">
 | |
| 	  <title>Tandberg TDC 3600</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is
 | |
| 	    <literal>TANDBERG TDC 3600 =08:</literal> <literal>type 1
 | |
| 	      removable SCSI 2</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a QIC tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 150/250MB.</para>
 | |
| 	  
 | |
| 	  <para>This drive has quirks which are known and work around code is
 | |
| 	    present in the SCSI tape device driver (&man.st.4;).
 | |
| 	    Upgrading the firmware to XXX version will fix the quirks and
 | |
| 	    provide SCSI 2 capabilities.</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 80kB/s.</para>
 | |
| 	  
 | |
| 	  <para>IBM and Emerald units will not work.  Replacing the firmware
 | |
| 	    EPROM of these units will solve the problem.</para>
 | |
| 	      
 | |
| 	  <para>Reported by: &a.msmith;</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-tandberg3620">
 | |
| 	  <title>Tandberg TDC 3620</title>
 | |
| 	  
 | |
| 	  <para>This is very similar to the <link
 | |
| 	      linkend="hw-storage-tandberg3600">Tandberg TDC 3600</link>
 | |
| 	    drive.</para>
 | |
| 	      
 | |
| 	  <para>Reported by: &a.joerg;</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-tandberg3800">
 | |
| 	  <title>Tandberg TDC 3800</title>
 | |
| 
 | |
| 	  <para>The boot message identifier for this drive is
 | |
| 	    <literal>TANDBERG TDC 3800 =04Y</literal> <literal>Removable
 | |
| 	      Sequential Access SCSI-2 device</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a QIC tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 525MB.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: &a.jhs;</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-tandberg4222">
 | |
| 	  <title>Tandberg TDC 4222</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is
 | |
| 	    <literal>TANDBERG TDC 4222 =07</literal> <literal>type 1 removable
 | |
| 	      SCSI 2</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a QIC tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 2.5GB.  The drive will read all cartridges
 | |
| 	    from the 60 MB (DC600A) upwards, and write 150 MB (DC6150)
 | |
| 	    upwards.  Hardware compression is optionally supported for the 2.5
 | |
| 	    GB cartridges.</para>
 | |
| 	      
 | |
| 	  <para>This drives quirks are known and pre-compiled into the SCSI
 | |
| 	    tape device driver (&man.st.4;) beginning with FreeBSD
 | |
| 	    2.2-CURRENT.  For previous versions of FreeBSD, use
 | |
| 	    <command>mt</command> to read one block from the tape, rewind the
 | |
| 	    tape, and then execute the backup program (<command>mt fsr 1; mt
 | |
| 	      rewind; dump ...</command>)</para>
 | |
| 	      
 | |
| 	  <para>Data transfer rate is 600kB/s (vendor claim with compression),
 | |
| 	    350 KB/s can even be reached in start/stop mode. The rate
 | |
| 	    decreases for smaller cartridges.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: &a.joerg;</para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-wangtek5525es">
 | |
| 	  <title>Wangtek 5525ES</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>WANGTEK
 | |
| 	      5525ES SCSI REV7 3R1</literal> <literal>type 1 removable SCSI
 | |
| 	      1</literal> <literal>density code 0x11, 1024-byte
 | |
| 	      blocks</literal></para>
 | |
| 	      
 | |
| 	  <para>This is a QIC tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 525MB.</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is 180kB/s.</para>
 | |
| 	  
 | |
| 	  <para>The drive reads 60, 120, 150, and 525MB tapes.  The drive will
 | |
| 	    not write 60MB (DC600 cartridge) tapes.  In order to overwrite 120
 | |
| 	    and 150 tapes reliably, first erase (<command>mt erase</command>)
 | |
| 	    the tape.  120 and 150 tapes used a wider track (fewer tracks per
 | |
| 	    tape) than 525MB tapes. The <quote>extra</quote> width of the
 | |
| 	    previous tracks is not overwritten, as a result the new data lies
 | |
| 	    in a band surrounded on both sides by the previous data unless the
 | |
| 	    tape have been erased.</para>
 | |
| 	      
 | |
| 	  <para>This drives quirks are known and pre-compiled into the SCSI
 | |
| 	    tape device driver (&man.st.4;).</para>
 | |
| 	  
 | |
| 	  <para>Other firmware revisions that are known to work are:
 | |
| 	    M75D</para>
 | |
| 	  
 | |
| 	  <para>Reported by: Marc van Kempen <email>marc@bowtie.nl</email>
 | |
| 	    <literal>REV73R1</literal> Andrew Gordon
 | |
| 	    <email>Andrew.Gordon@net-tel.co.uk</email>
 | |
| 	    <literal>M75D</literal></para>
 | |
| 	</sect3>
 | |
| 
 | |
| 	<sect3 id="hw-storage-wangtek6200">
 | |
| 	  <title>Wangtek 6200</title>
 | |
| 	  
 | |
| 	  <para>The boot message identifier for this drive is <literal>WANGTEK
 | |
| 	      6200-HS 4B18</literal> <literal>type 1 removable SCSI
 | |
| 	      2</literal> <literal>Sequential-Access density code
 | |
| 	      0x13</literal></para>
 | |
| 	  
 | |
| 	  <para>This is a DDS-1 tape drive.</para>
 | |
| 	  
 | |
| 	  <para>Native capacity is 2GB using 90m tapes.</para>
 | |
| 	  
 | |
| 	  <para>Data transfer rate is 150kB/s.</para>
 | |
| 	  
 | |
| 	  <para>Reported by: Tony Kimball <email>alk@Think.COM</email></para>
 | |
| 	</sect3>
 | |
|       </sect2>
 | |
|       
 | |
|       <sect2>
 | |
| 	<title>* Problem drives</title>
 | |
| 
 | |
| 	<para></para>
 | |
|       </sect2>
 | |
|     </sect1>
 | |
|     
 | |
|     <sect1>
 | |
|       <title>CDROM drives</title>
 | |
|       
 | |
|       <para><emphasis>Contributed by &a.obrien;.  23 November
 | |
| 	      1997.</emphasis></para>
 | |
|       
 | |
|       <para>Generally speaking those in <emphasis>The FreeBSD
 | |
| 	Project</emphasis> prefer SCSI CDROM drives over IDE CDROM
 | |
| 	drives.  However not all SCSI CDROM drives are equal.  Some
 | |
| 	feel the quality of some SCSI CDROM drives have been
 | |
| 	deteriorating to that of IDE CDROM drives.  Toshiba used to be
 | |
| 	the favored stand-by, but many on the SCSI mailing list have
 | |
| 	found displeasure with the 12x speed XM-5701TA as its volume
 | |
| 	(when playing audio CDROMs) is not controllable by the various
 | |
| 	audio player software.</para>
 | |
| 	  
 | |
|       <para>Another area where SCSI CDROM manufacturers are cutting corners is
 | |
| 	adherence to the <link linkend="scsi-further-reading">SCSI
 | |
| 	  specification</link>. Many SCSI CDROMs will respond to <link
 | |
| 	  linkend="scsi-rogue-devices">multiple LUNs</link> for its target
 | |
| 	address.  Known violators include the 6x Teac CD-56S 1.0D.</para>
 | |
|   </sect1>
 | |
| 
 | |